AMETEK CTS
VDS 200Q10 Series
Manual for Operation
V 1.00
7 / 35
5
FRAME BUS
EM Test internal communication bus. Daisy chain all equipment connected to the bus, terminate
at the end of the chain.
6
TRIGGER IN
External trigger IN signal
7
ANALOG IN
-10 / +10VDC. Connection to AutoWave or an external arbitrary waveform generator.
8
Mains switch
To power up the equipment
9
Mains fuse
230 Vac, 6.3 A, 5 x 20 mm
115 Vac, 10 A, 5 x 20 mm
100 Vac, 16 A, 5 x 20 mm
10 Mains input
Max. 16A, depending on power mains voltage.
11 IEEE 488 / GPIB
Parallel IEEE 488 interface to remote control the generator with a software tool.
12 USB Port
USB interface “USB B” connector. For data transfer a USB interface is available. The internal RS 232
interface is converted to USB standard. Therefore the user must set the same Baudrate in the device and
control software.
Interface is supported for iso.control, but not for autowave.control (either IEEE or FRAME BUS).
13 CN interface
Interface to other EM TEST devices, currently not used
14
FAIL1 / FAIL2
FAIL 1
can be used for failure detection at the DUT. If the input is set to ground (chassis) the generator
stops and terminate the test. The SW test routine than can be stopped completely continued at the break
point. A message of FAIL 1 is indicated in the LCD display as well as in the ISM software.
FAIL2
can be used for failure detection at the DUT. If the input is set to ground (chassis) the actual test
routine is paused as long as the low level signal is available at the FAIL 2 input. With no longer set to ground
signal the test procedure continues automatically. A message of FAIL 2 is indicated in the LCD display as
well as in the ISO.CONTROL software.