SAFETY INFORMATION FOR USERS OF LP-GAS

Propane (LP-Gas) is a flammable gas which can cause fires 

and explosions.  In its natural state, propane is odorless and 

colorless.  You may not know all the following safety precau-

tions which can protect both you and your family from an ac-

cident.  Read them carefully now, then review them point by 

point with the members of your household.  Someday when 

there may not be a minute to lose, everyone's safety will depend 

on knowing exactly what to do.  If, after reading the following 

information, you feel you still need more information, please 

contact your gas supplier.

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas 

because of the odorant put in the LP-Gas. 

That's your signal to go into immediate action!

• 

Do not operate electric switches, light matches, use your phone.  

Do not do anything that could ignite the gas.

•   Get everyone out of the building, vehicle, trailer, or area. Do 

that IMMEDIATELY.

•   Close all gas tank or cylinder supply valves.
•   LP-Gas is heavier than air and may settle in low areas such 

as basements.  When you have reason to suspect a gas leak, 

keep out of basements and other low areas.  Stay out until 

firefighters declare them to be safe.

•   Use your neighbor's phone and call a trained LP-Gas service 

person and the fire department.  Even though you may not 

continue to smell gas, do not turn on the gas again.  Do not 

re-enter the building, vehicle, trailer, or area.

•  

Finally, 

let the service man and firefighters check for escaped 

gas.  Have them air out the area before you return.  Properly 

trained  LP-Gas  service  people  should  repair  the  leak,  then 

check and relight the gas appliance for you.

NO ODOR DETECTED - ODOR FADE

Some people cannot smell well. Some people cannot smell the 

odor of the chemical put into the gas. You must find out if you can 

smell the odorant in propane. Smoking can decrease your ability to 

smell. Being around an odor for a time can affect your sensitivity or 

ability to detect that odor. Sometimes other odors in the area mask 

the gas odor. People may not smell the gas odor or their minds are 

on something else. Thinking about smelling a gas odor can make 

it easier to smell.

The odorant in LP-gas is colorless, and it can fade under some 

circumstances. For example, if there is an underground leak, the 

movement of the gas through soil can filter the odorant. Odorants in 

LP-Gas also are subject to oxidation. This fading can occur if there 

is rust inside the storage tank or in iron gas pipes.

The odorant in escaped gas can adsorb or absorb onto or into 

walls, masonry and other materials and fabrics in a room. That will 

take some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could 

vary at different levels. Since it is heavier than air, there may be 

more odor at lower levels. Always be sensitive to the slightest gas 

odor. If you detect any odor, treat it as a serious leak. Immediately 

go into action as instructed earlier.

SOME POINTS TO REMEMBER

• 

Learn  to  recognize  the  odor  of  LP-gas.  Your  local  LP-Gas 

Dealer can give you a "Scratch and Sniff" pamphlet. Use it to 

find out what the propane odor smells like. If you suspect that 

your LP-Gas has a weak or abnormal odor, call your LP-Gas 

Dealer.

• 

If you are not qualified, do not light pilot lights, perform service, 

or make adjustments to appliances on the LP-Gas system. If 

you are qualified, consciously think about the odor of LP-Gas 

prior to and while lighting pilot lights or performing service or 

making adjustments.

•  Sometimes a basement or a closed-up house has a musty 

smell that can cover up the LP-Gas odor. Do not try to light 

pilot lights, perform service, or make adjustments in an area 

where the conditions are such that you may not detect the odor 

if there has been a leak of LP-Gas.

•  Odor fade, due to oxidation by rust or adsorption on walls of 

new cylinders and tanks, is possible. Therefore, people should 

be particularly alert and careful when new tanks or cylinders 

are placed in service. Odor fade can occur in new tanks, or 

reinstalled old tanks, if they are filled and allowed to set too 

long before refilling. Cylinders and tanks which have been out 

of service for a time may develop internal rust which will cause 

odor fade. If such conditions are suspected to exist, a periodic 

sniff test of the gas is advisable. If you have any question about 

the gas odor, call your 

LP

-gas dealer. A periodic sniff test of the 

LP

-gas is a good safety measure under any condition.

• 

If, at any time, you do not smell the LP-Gas odorant and you 

think you should, assume you have a leak. Then take the same 

immediate action recommended above for the occasion when 

you do detect the odorized LP-Gas.

• 

If you experience a complete "gas out," (the container is under 

no vapor pressure), turn the tank valve off immediately. If the 

container valve is left on, the container may draw in some air 

through openings such as pilot light orifices. If this occurs, some 

new internal rusting could occur. If the valve is left open, then 

treat the container as a new tank. Always be sure your con

-

tainer is under vapor pressure by turning it off at the container 

before it goes completely empty or having it refilled before it is 

completely empty.

Содержание FAW-55-1SPP

Страница 1: ...these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in...

Страница 2: ...burner ignition devices are located not less than 18 457mm above the floor Such equipment shall be located or protected so it is not subject to physical damage by a moving vehicle Specifications Model...

Страница 3: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clo...

Страница 4: ...onnected to a chimney flue serving a separate solid fuel burning appliance 3 Uninsulated Single Wall Metal Pipe shall not be used outdoors in cold climates for venting gas utilization equipment 4 Atte...

Страница 5: ...connec tion Also refer to Figure 2 for positioning the furnace on wall and for locating gas line connection Locating Gas Supply The gas line can enter the furnace either though the floor or wall The...

Страница 6: ...air in the gas line it is suggested that a match be used The match will light the pilot faster than the piezo under this condition Attention The 7 8 22mm strain relief bushing is located within the s...

Страница 7: ...will be blue extending past the thermocouple The flame will surround the thermocouple just be low the tip Natural gas pilots require adjusting when the inlet gas pressure is above 5 w c 1 245kPa Remov...

Страница 8: ...Fan Motor The upper front panel the shroud sur rounding the fan blade and fan blade must be removed See oiling the Motor paragraph on page 7 Spark Igniter Does Not Light Pilot With air in the gas lin...

Страница 9: ...knob clockwise to OFF 6 Wait ten 10 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to...

Страница 10: ...808 PILOT TUBING 25 DV562 LOWER FRONT PANEL 26 DV824 FRONT BURNER 27 P8842 MAIN BURNER ORIFICE NATURAL GAS TWO REQUIRED 27 P8853 MAIN BURNER ORIFICE LP GAS TWO REQUIRED 28 DV687 MANIFOLD AND PLATE ASS...

Страница 11: ...32192 1 0314 Page 11...

Страница 12: ...oval elbows 3 Single story type B 1 gas vents require a baseplate and one pair of ceiling plate spacers 4 Multi story type B 1 gas vents require a baseplate one pair of ceiling plate spacers at the fi...

Страница 13: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numb...

Страница 14: ...32192 1 0314 Page 14 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 15: ...A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might r...

Страница 16: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Страница 17: ...tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez a aucun interrupteur Ne pas vous servir des t l phones se trouvant dans le b ti ment o vous...

Страница 18: ...syst me de com mande et les commandes de gaz qui ont t en contact avec l eau Ce radiateur ne doit pas tre branch une chemin e servant un autre appareil br lant un combustible solide A cause des hautes...

Страница 19: ...que les pompiers vous assurent de la s ret de ces endroits avant d y aller Utiliser le t l phone de votre voisin et appeler les pompiers et une personne entra n e avec le propane Ne pas ouvrir les so...

Страница 20: ...tall s dans un endroit o la facilit delaventilationpermetunecombustiondegazsatisfaisanteetun chappe ment convenable sous des conditions normales Dans les b timents de construction conventionnelle de b...

Страница 21: ...tant est chang de place Un guide est fourni dans l emballage du radiateur pour vous aider localiser la connexion pour la ligne de gaz Aussi r f rer la Figure 2 pour positionner le radiateur sur le mur...

Страница 22: ...de 3 914mm du compartiment des contr les au bas du radiateur 2 Enlever l entr e d fon able de 7 8 22mm du c t du panneau ap propri 3 Introduire le bouchon de nylon de l assemblage de la fiche de 3 914...

Страница 23: ...que le radiateur ait fonctionn il se peut que les ouvertures du br leur soient bloqu es par des mati res trang res venant de l air de combustion Donc un nettoyage du br leur peut tre exig pour obteni...

Страница 24: ...ation lequel doit tre install et entretenu correctement ou lorsque vous tripotez avec le syst me de fermeture de s ret de l vent peut causer un empoissonnement au monoxide de carbone CO et possiblemen...

Страница 25: ...tion La veilleuse est suppos e rester allumer Si elle s teint recommencer les tapes 5 jusqu 10 Si le bouton ne revient pas sa position lorsque vous le rel chez arr ter et appeler imm diatement un tech...

Страница 26: ...intervalles jusqu ce qu elle s allume Si l lectrode ne Produit Pas d tincelle 1 V rifier les connexions des fils lectriques 2 V rifier la distance du br leur de la veilleuse au bout de l lectrode Doi...

Страница 27: ...s ret de l vent 16 8720130 Manchon 17 11765 Assemblage du compartiment d interrupteur 18 DV 832 Couvercle du compartiment d interrupteur 19 912073 Contr le de tol rance 20 R 1941 Contr le du ventilat...

Страница 28: ...12428 7 0314 Page 12 Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62222 0529...

Страница 29: ...de base et une paire d entretoises pour la plaque du plafond 4 Les vents gaz de type B 1 pour plus d un tage exige une plaque de base une paire d entretoises pour la plaque du pla fond au plafond du...

Страница 30: ...mages pouvant r sulter de l emploi de l emploi abusif ou d une installation incorrecte de cet appareil Frais de d placement de diagnostic et de transport des pi ces sous garantie vers et depuis l usin...

Отзывы: