background image

Содержание 035-16329-002

Страница 1: ...from fuel combustion which are known to the State of California to cause cancer birth defects or other reproductive harm Also operation installation and servicing of this product could expose you to airborne particles of glasswool fibers known to the State of California to cause cancer through inhalation Use of furnace or air conditioning components that are not included in the Inter tek Testing S...

Страница 2: ... device which is not approved 9 Problemscaused by improper installationof the furnace flue assembly roofjack 10 Adding a roofjack extension because of unusualwind con ditions or snowconditions 11 Adjusting or calibrating the thermostat 12 Problems caused by construc tiondebds which has fallen into the flue or combustion air openings 13 Replacement of fuses 14 Problems caused by odfice plugged or r...

Страница 3: ... and hold Immediately light the pilot with a match use match holder provided Continue to hold the control lever for about one 1 minute after the pilot is lit Release the lever and it will spring back to the PILOT position Pilot should remain lit If it goes out repeat steps 5 through 9 above If the lever does not spdng back when released stop and immediately call your service technician or gas supp...

Страница 4: ...ingcontinuously due to a heat buildupwithinthe 10 furnace by a combinationof STOP Read the safety infor mation Set the thermostat to the low est setting or OFF Turn off all electdc power to the furnace This appliance does not have a pilot It is equipped with an igni tion device which automatically lights the burner Do not try to light the burner by hand Remove upper door panel Move gas valve contr...

Страница 5: ...ulationblower will run 9 When roomthermostat is setis fled the circuitto the furnace control board is opened The circuitto the combustionair blowerand the gas valve is opened and the burner is extin guished Then the furnace con trol board will keep the circulatingblower running for a fixed pedod of time to allow additionalheat to be drawn from the heat exchanger DIAGNOSTIC LIGHT If furnace does no...

Страница 6: ...cking for correct opera tion such as burner failing to ignite or to turn off sootyflame etc cell your nearest authorized service technician as shown in the Service Center List included in the home owner envelope IF FURNACE FAILS TO OPERATE PROPERLY 1 Check setting of thermostat and positionof heat cool switch if air conditioning is installed If a set back type thermostatis employed be sure that th...

Страница 7: ... cold weather ice may form on the fumace roof jack crown Small amounts of ice form ing on the roof jack will present no problem to proper furnace opera tion However excessive ice for mation could restrict the combustion air supply to the burner causing inefficient burner opera tion When the temperature is very cold near zero or below it is recom mended that the roof jack be inspected every day or ...

Страница 8: ...uired to make the furnace operate properly These furnaces are shipped fi om the factory with a natural gas orifice If you will be operating this furnace on LP liquid propane gas it will also be necessary to have the furnace converted The correct LP orifice is supplied with the furnace to allow operation at elevations below 2 000 feet If the furnace will be operating on LP gas at elevations above 2...

Отзывы: