39235-1-0219
Page 15
aLTeRnaTe on/oFF sWITcH InsTaLLaTIon
Cast Iron Surrounds
Cast Iron Surrounds require a surround adaptor kit. See page 9
for kit information.
1. Find the coiled low voltage wire assembly and ON/OFF
switch located in the instruction packet.
2a. Attach the flag terminal ends to the
“
TH/TP
”
and
“
TH
”
terminals on the front terminal block of the MV gas valve.
see Figure 18.
2b. Attach the flag terminals to the green and white wire
terminals located in the bottom of the insert near the gas
valve.
see Figures 19 and 20.
3. Run the low voltage alternate switch wires up the back of
the right or left cast surround leg. Then secure them with the
wire clips provided.
4. Install the switch bracket with screws as shown in
Figure 6
to the back of the cast surround leg.
Figure 6
NOTICE:
For right side leg installation, reverse switch
position in bracket.
5. Install ON/OFF switch, and connect low-voltage wires from
gas valve (MV) or control module (IP).
6. Attach cast surround panel assembly to the insert. Place the
cast surround assembly to the face of the insert. Align the
inside brackets on the cast surround with the flanges on the
insert. Install four #8 x 1/2 truss head sheet metal screws to
secure the surround.
Содержание VFLC10IN32N-1
Страница 13: ...39235 1 0219 Page 13 VFLC 10 20 IN FIREPLACE SURROUND DIMENSIONS ds20433bl ds20763bl 34 21 1 2 1 40 24 1 2 1...
Страница 14: ...39235 1 0219 Page 14 VFLC28IN FIREPLACE SURROUND DIMENSIONS ds28433bl ds28763bl 37 24 1 2 1 43 27 1 2 1...
Страница 42: ...39235 1 0219 Page 42 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 43: ...39235 1 0219 Page 43 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...