39235-1-0219
Page 19
Propane Gas
will have a manifold pressure approximately 10.0"w.c.
at the pressure regulator outlet with the inlet pressure to the pressure
regulator from a minimum of 11.0"w.c. for the purpose of input
adjustment to a maximum of 13.0"w.c. .
Control Valve - Gas Pressure Check
The valve regulator controls the burner pressure which should be
checked at the pressure test point. Turn captured screw counter
clockwise 2 or 3 turns and then place tubing to pressure gauge over
test point (Use test point “A” closest to control knob). After taking
pressure reading,
be sure and turn captured screw clockwise
firmly to re-seal.
Do not over torque. Check for gas leaks.
Checking Manifold Pressure
MILLIVOLT VALVES
Natural Gas
will have a manifold pressure of approximately 3.5" w.c.
for maximum input or 1.7" w.c. for minimum input at the pressure
regulator outlet with the inlet pressure to the pressure regulator
from a minimum of 4.5" w.c. for the purpose of input adjustment to
a maximum of 10.5" w.c.
Propane Gas
will have a manifold pressure approximately 10.0"w.c.
(2.49kPa) for maximum input or 4.9"w.c. for minimum input at the
pressure regulator outlet with the inlet pressure to the pressure
regulator from a minimum of 11.0"w.c. for the purpose of input
adjustment to a maximum of 13.0"w.c.
INTERMITTENT PILOT VALVES
Natural Gas
will have a manifold pressure of approximately 3.5"
w.c. at the pressure regulator outlet with the inlet pressure to the
pressure regulator from a minimum of 7.0" w.c. for the purpose of
input adjustment to a maximum of 10.5" w.c.
Gas sUPPLY (conT'D)
(coMBUsTIBLe) cLeaRances
8”
MINIMUM CLEARANCE TO PERPENDICULAR
SIDE-WALL FROM INSIDE EDGE OF FIREBOX - 8”
Figure 12
FINISHED WALL OR
FIREPLACE FACE
FLAT MANTEL
SHELF
33”
29”
31”
35”
37”
39”
2”
6”
4”
8”
10”
12”
VFLC20 Series -
Figure 13
FINISHED WALL OR
FIREPLACE FACE
FLAT MANTEL
SHELF
41”
37”
39”
43”
45”
47”
2”
6”
4”
8”
10”
12”
VFLC28 Series -
Figure 14
Содержание VFLC10IN32N-1
Страница 13: ...39235 1 0219 Page 13 VFLC 10 20 IN FIREPLACE SURROUND DIMENSIONS ds20433bl ds20763bl 34 21 1 2 1 40 24 1 2 1...
Страница 14: ...39235 1 0219 Page 14 VFLC28IN FIREPLACE SURROUND DIMENSIONS ds28433bl ds28763bl 37 24 1 2 1 43 27 1 2 1...
Страница 42: ...39235 1 0219 Page 42 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 43: ...39235 1 0219 Page 43 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...