39235-1-0219
Page 28
1. STOP! Read the safety information above.
2. Turn OFF electric power to the appliance.
3. Remove barrier screen assembly or bottom louver if included.
4. Turn gas shut-off counterclockwise
to “On” position.
5. Wait ten (10) minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow “B” in
the safety information above on this page. If you do not smell
gas, go to the next step.
6. Turn ON electric power to the appliance.
7. Find pilot - Follow metal tube from gas control. The pilot is
behind the burner on the right side.
8. Turn main flame to on. If the pilot does not light within 60
seconds, stop and go to Step 5.
9.
NOTE:
There is a CPI/IPI switch behind the right side panel
that allows for a continuous standing pilot mode or an
intermittent pilot mode. See appliance manual for location
of this switch. If the pilot or burner does not stay lit (in the
standing pilot mode), stop and immediately call a qualified
service technician or gas supplier.
10. If the burner or pilot does not operate properly after several
tries, turn the gas shut-off clockwise
to “OFF” and
call your service technician or gas supplier.
11. Replace barrier screen assembly or close bottom louver
assembly.
12. Operation of the gas valve is controlled by a manual on/
off switch or a hand held remote control. Refer to remote
instructions for detailed operation information.
A. This appliance has a pilot which must be lighted by hand. When
lighting the pilot, follow these instructions exactly.
B. Before lighting smell all around the appliance area for gas. Be
sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
What To Do If You Smell Gas
• Do not try to light any appliance.
• Do not touch any electrical switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
don't try to repair it; call a qualified service technician. Force
or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
1. Set REMOTE/OFF/ON switch to OFF.
2. Turn off all electric power to the appliance if service is to be
performed (if applicable).
3. Lower bottom louver assembly.
4. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
5. Close bottom louver assembly.
INTERMITTENT PILOT LIGHTING INSTRUCTIONS
OFF
ON
GAS SHUT-OFF VALVE
PILOT
ELECTRODE
FLAME
SENSOR
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
Содержание VFLC10IN32N-1
Страница 13: ...39235 1 0219 Page 13 VFLC 10 20 IN FIREPLACE SURROUND DIMENSIONS ds20433bl ds20763bl 34 21 1 2 1 40 24 1 2 1...
Страница 14: ...39235 1 0219 Page 14 VFLC28IN FIREPLACE SURROUND DIMENSIONS ds28433bl ds28763bl 37 24 1 2 1 43 27 1 2 1...
Страница 42: ...39235 1 0219 Page 42 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 43: ...39235 1 0219 Page 43 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...