
39235-1-0219
Page 29
Flames from the pilot and the main flame should be visually checked.
In normal operation at full rate after 10 to 15 minutes, the flame
appearance should be a line of yellow tipped flames.
NOTICE:
All flames will be random by design, flame height will go
up and down.
Avoid any drafts that alter burner flame patterns. Do not allow fans to
blow directly into fireplace. Do not place a blower inside the burner
area of the firebox. Ceiling fans may create drafts that alter flame
patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components
of this appliance are treated with certain oils, films or bonding agents.
These chemicals are not harmful, but may produce annoying smoke
and smells as they are burned off during the initial operation of the
appliance, possibly causing headaches or eye or lung irritation. This
is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner
at the highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in will be slight and will disappear with
continued use.
PERIODIC CLEANING – Refer to parts diagram for location of
items discussed below.
•
Do not use cleaning fluid to clean any part of heater.
•
Remove loose particles and dust from the burner areas and
controls.
•
Inspect and clean burner air intake hole. Remove lint or particles
with brush. Failure to keep air intake hole clean will result in
sooting and poor combustion.
annUaL cLeanInG/InsPecTIon – Refer to parts diagram for
location of items discussed below.
•
Inspect and clean burner air intake hole. Remove lint or particles
with vacuum or brush. Failure to keep air intake hole clean will
result in sooting and poor combustion.
•
Inspect and clean all burner ports.
•
Inspect ODS pilot for operation and accumulation of lint at air
intake holes.
•
Verify flame pattern for proper operation.
•
Verify smooth and responsive ignition of main burner.
oPeRaTIon InsTRUcTIons/FLaMe aPPeaRance
Содержание VFLC10IN32N-1
Страница 13: ...39235 1 0219 Page 13 VFLC 10 20 IN FIREPLACE SURROUND DIMENSIONS ds20433bl ds20763bl 34 21 1 2 1 40 24 1 2 1...
Страница 14: ...39235 1 0219 Page 14 VFLC28IN FIREPLACE SURROUND DIMENSIONS ds28433bl ds28763bl 37 24 1 2 1 43 27 1 2 1...
Страница 42: ...39235 1 0219 Page 42 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 43: ...39235 1 0219 Page 43 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...