38712-2-0719
Page 78
intermittent pilot control sYstem troUbleshooting
Burner & pilot light but will not stay lit
Flame sensor dirty
Clean pilot sensor
Low gas pressure
Check gas supply pressure
Not enough fresh air for pilot
open door or window - ventilate
Clogged or dirty burner ports
Clean burner ports
(For fireplace equipped with optional ther
-
mostat or thermostat remote) Room tem
-
perature is higher than thermostat setting
move (optional) remote away from fire
-
place
Set higher temperature on (optional)
remote/thermostat
(optional) Remote control batteries failing
Replace batteries in remote transmitter
and receiver
Faulty pilot or thermocouple
Replace pilot
Incorrect burner flame
Incorrect gas supply or pressure
Check gas supply pressure
Blocked orifice
Check orifice opening
Clogged or dirty burner ports
Clean burner ports
Faulty valve
Replace valve
High altitude
Adjust orifice size for altitude
Backfire of burner
Blocked orifice
Check orifice opening
Clogged or dirty burner ports
Clean burner ports
Low gas pressure
Check gas supply pressure
Fireplace produces unwanted odors
Vapors from paint, hairspray, glue, etc.
Ventilate room until odor stops. Do not use
paint, hairspray, glue, etc around fireplace
Initial burn-off of manufacturing chemicals
Ventilate room until odor stops
Whistle noise from fireplace
Check gas pressure
Adjust gas pressure to recommended
setting.
Air in gas line
Bleed lines
Control knob not in fully open position
open control knob to full position
Spiral gas flex line pinched or too small
diameter line
Straighten flex line where pinched or re
-
place gas feed line with larger diameter
Содержание MILLIVOLT DVCD32FP30
Страница 47: ...38712 2 0719 Page 47 7 Tuck Log G under Log C and onto pin of Log B LOG PLACEMENT for DVCD32 fireplaces...
Страница 48: ...38712 2 0719 Page 48 Log placement is complete LOG PLACEMENT for DVCD32 fireplaces...
Страница 57: ...38712 2 0719 Page 57 LOG PLACEMENT For DVCD36 fireplaces Log placement is complete...
Страница 67: ...38712 2 0719 Page 67 Log placement is complete LOG PLACEMENT for DVCD42 fireplaces...
Страница 93: ...38712 2 0719 Page 93 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 94: ...38712 2 0719 Page 94 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 95: ...38712 2 0719 Page 95 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...