38712-2-0719
Page 21
VENTING FIREPLACE - TOP (CONT’D)
Example of possible venting systems using two 90° elbows.
V is listed as minimum vertical dimensions and H1 + H2 is listed
as total of maximum horizontal dimensions. The maximum
vertical and horizontal distances for two 90° elbows as shown in
Figure 33 is 20 feet (6.1 m).
Attention: Refer to Figure 30 for additional venting requirements.
FIRESTOP AT
CEILING LEVEL
SEE GRAPH FOR PERMISSIBLE “H” AND “V” DIMENSIONS
NOTE: H1 AND H2 MUST BE ADDED TOGETHER TO USE CHART
V
H2
H1
figure 33
B
C
A
CENTER OF ELBOW
STRAIGHT OUT
(MINIMUM)
D
C
B
fireplace
series
hard elboW dimensions (inches)
a
b
c
d
dvcd32fP
41-1/2
4-1/2
6-1/2
9-1/8
dvcd36fP
41-1/2
4-1/2
6-1/2
9 1/8
dvcd42fP
43-1/2
4-1/2
6-1/2
9 1/8
fireplace
series
fleX pipe 90 degree bend
dimensions (inches)
a
b
c
d
dvcd32fP
43
4-1/2
6-1/2
9-1/8
dvcd36fP
43
4-1/2
6-1/2
9-1/8
dvcd42fP
45
4-1/2
6-1/2
9-1/8
minimum hole location dimensions for through the wall horizontal
installations with 90 degree elbow off top of fireplace.
figure 34
Содержание MILLIVOLT DVCD32FP30
Страница 47: ...38712 2 0719 Page 47 7 Tuck Log G under Log C and onto pin of Log B LOG PLACEMENT for DVCD32 fireplaces...
Страница 48: ...38712 2 0719 Page 48 Log placement is complete LOG PLACEMENT for DVCD32 fireplaces...
Страница 57: ...38712 2 0719 Page 57 LOG PLACEMENT For DVCD36 fireplaces Log placement is complete...
Страница 67: ...38712 2 0719 Page 67 Log placement is complete LOG PLACEMENT for DVCD42 fireplaces...
Страница 93: ...38712 2 0719 Page 93 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 94: ...38712 2 0719 Page 94 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 95: ...38712 2 0719 Page 95 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...