NOTICE
: The termination cap must pass through the wall
firestop from the exterior of the building. Adjust the termination
cap to its final exterior position on the building.
caUtion
The termination cap must be positioned so that the arrow is
pointing up. failure to properly position the parts may result
in a hazardous situation.
Attach the termination cap with the four wood screws provided.
Before attachment of the termination, run a bead of silicone
sealant rated above 250°F on its outside edge to make a seal to
the exterior wall.
caUtion
replace the wood screws with the appropriate fasteners for
use on stucco, brick, concrete or other types of siding. Failure
to use the proper fasteners may result in a hazardous situation.
caUtion
Install a vinyl siding standoff if the exterior walls are finished
with vinyl siding or materials that could become discolored
or warp.
Install the vinyl siding standoff between the vent termination
and the exterior wall. see figure 52. this horizontal vent
termination bolts onto the flat portion of the vinyl siding
standoff, so an air space will exist between the wall and the
termination cap.
attention
vinYl soffit, vinYl ceiling, vinYl overhang disclaimer
clearances are to heat resistant material (i.e. wood, metal).
this does not include vinyl. empire comfort systems will not
be held responsible for heat damage caused from terminating
under vinyl overhangs, vinyl ceilings or vinyl ventilated/
unventilated soffits.
figure 52
Snorkel terminations are available for installations requiring
a vertical rise of the building.
see figure 53.
Provide proper
drainage to prevent water from entering the snorkel termination
if it will be installed below grade (i.e. in a basement). Refer to
(figure 54).
Do not attempt to enclose the Snorkel within the wall
or any other type of enclosure.
ADEQUATE
DRAINAGE
SNORKEL
12” MINIMUM
OR EXPECTED
SNOW LEVEL
figure 53
(Snorkel or Snowlevel Clearance Required)
12” MINIMUM
OR EXPECTED
SNOW LEVEL
SNORKEL
figure 54
(Snorkel or Snowlevel Clearance Required)
horizontal termination
Содержание MILLIVOLT DVCD32FP30
Страница 47: ...38712 2 0719 Page 47 7 Tuck Log G under Log C and onto pin of Log B LOG PLACEMENT for DVCD32 fireplaces...
Страница 48: ...38712 2 0719 Page 48 Log placement is complete LOG PLACEMENT for DVCD32 fireplaces...
Страница 57: ...38712 2 0719 Page 57 LOG PLACEMENT For DVCD36 fireplaces Log placement is complete...
Страница 67: ...38712 2 0719 Page 67 Log placement is complete LOG PLACEMENT for DVCD42 fireplaces...
Страница 93: ...38712 2 0719 Page 93 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 94: ...38712 2 0719 Page 94 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 95: ...38712 2 0719 Page 95 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...