38712-2-0719
Page 6
accessories
The following accessories are available from your empire Dealer.
accessories
description
model
ember Bed Kit
eK1
Platinum Glowing embers
Pe20
Variable Speed Blower
fBB4
Flex Gas Line, 24-in
Stainless Steel
GF24
NOTICE
: empire Comfort Systems does not offer a mantel for
this series of fireplaces.
control options
description
model
Battery Remote, on/oFF
FRBC
Battery Remote, Thermostat
FRBTC
Remote, electric
FReC
Remote, Programmable
FRBTP
Wall Switch, on/off
FWS1
Wall Thermostat – Reed Switch
TmV
Wall Thermostat – Wireless
TRW
vent kits
part no.
description
dvvK4TSP
Top Vent Kit (horizontal) – 4-1/2 to 6
-inch
wall
thickness
dvvK4TP
Top Vent Kit (horizontal) – 8 to 12
-inch
wall
thickness
DVVK4RP Rear Vent Kit (horizontal – 5 to 7
-inch
wall
thickness
dvvK4vP
Vertical Vent Kit
dvvK4f
Horizontal Flex Vent Kit (4-foot flex)
DVVK4Re Horizontal round termination (wall thickness up
to 13-3/4
inches
)
DV822
Vinyl Siding Kit for DVVK-4Re
conversion kits
kit #
conversion type
Used on
18816
Propane to Natural
dvcd32fP3
18456
Natural to Propane
dvcd32fP3
18817
Propane to Natural
dvcd36fP3
18442
Natural to Propane
dvcd36fP3
18818
Propane to Natural
dvcd42fP3
18814
Natural to Propane
dvcd42fP3
32881
Propane to Natural
dvcd32fP7
32880
Natural to Propane
dvcd32fP7
31759
Propane to Natural
dvcd36fP7
32882
Natural to Propane
dvcd36fP7
31761
Propane to Natural
dvcd42fP7
31760
Natural to Propane
dvcd42fP7
specifications
dvcd32
natural gas
dvcd32
propane gas
dvcd36
natural gas
dvcd36
propane gas
dvcd42
natural gas
dvcd42
propane gas
Input BTU/Hr maximum
18,000
18,000
20,000
20,000
25,000
25,000
Input BTU/Hr minimum
14,000
14,000
14,000
16,500
18,000
19,500
KWH maximum
5.3
5.3
5.9
5.9
7.3
7.3
KWH minimum
4.1
4.1
4.1
4.1
5.3
5.3
orifice
#46 (0.081
inch
)
#56 (0.0465
inch
)
2.10mm
#55 (0.052
inch)
#42 (0.0935
inch)
1.45mm
Air Shutter opening (inches)
1/16
1/4
1/16
5/16
3/16
5/16
Gas Inlet Shutoff Valve (pipe)
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
NOTICE
: Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
gas sUpplY pressUres (inches water column)
gas type
maximum
minimum
manifold
Natural
14.0
4.5
3.5
Propane
14.0
10.5
10.0
Содержание MILLIVOLT DVCD32FP30
Страница 47: ...38712 2 0719 Page 47 7 Tuck Log G under Log C and onto pin of Log B LOG PLACEMENT for DVCD32 fireplaces...
Страница 48: ...38712 2 0719 Page 48 Log placement is complete LOG PLACEMENT for DVCD32 fireplaces...
Страница 57: ...38712 2 0719 Page 57 LOG PLACEMENT For DVCD36 fireplaces Log placement is complete...
Страница 67: ...38712 2 0719 Page 67 Log placement is complete LOG PLACEMENT for DVCD42 fireplaces...
Страница 93: ...38712 2 0719 Page 93 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 94: ...38712 2 0719 Page 94 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 95: ...38712 2 0719 Page 95 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...