38712-2-0719
Page 71
1. Stop! Read the safety information above.
2. Set RemoTe/oFF/oN switch to oFF.
3. Turn off all electric power to the fireplace (if applicable).
4. open bottom louver if included, or remove the barrier
screen assembly.
5. Push in gas control knob slightly and turn clockwise
to
“
oFF.
”
NOTICE:
Knob cannot be turned from
“
PILoT
”
to
“
oFF
”
unless
knob is pushed in slightly. Do not force.
6. Wait ten minutes to clear out any gas. Then smell for gas,
including near the floor. If you then smell gas, SToP!
Follow
“
B
”
in the safety information above. If
you do not smell gas, go to the next step.
7. Find pilot - Follow metal tube from gas
control. The pilot is behind the burner
on the right side.
8. Turn gas control knob
counterclockwise
to
“
PILoT.
”
9. Push in control knob all the way and hold in.
Repeatedly push the piezo ignitor button until the pilot
is lit. Continue to hold the control knob in for about one
minute after the pilot is lit. Release knob, and it will pop
back up. Pilot should remain lit. If it goes out, repeat
steps 5 through 9.
• If the control knob does not pop up when
released, SToP and ImmeDIATeLY call a
qualified service technician or gas supplier.
• If the pilot will not stay lit after several tries,
turn the gas control knob to
“
oFF
”
and call
your service technician or gas supplier.
10. Turn gas control knob counterclockwise
to
“
oN.
”
11. Close bottom louver if included, or replace the barrier
screen assembly.
12. Turn on all electric power to the fireplace (if applicable).
13. Set RemoTe/oFF/oN switch to desired setting.
A. This fireplace has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. Before lighting smell all around the fireplace area for gas.
Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What To Do If You Smell Gas
• Do not try to light any appliance.
• Do not touch any electrical switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it; call a qualified ser
-
vice technician. Force or attempted repair may result in
a fire or explosion.
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service technician
to inspect the fireplace and to replace any part of the
control system and any gas control which has been
under water.
1. Set RemoTe/oFF/oN switch to oFF.
2. Turn off all electric power to the fireplace if service is to be
performed (if applicable).
3. open bottom louver assembly or remove barrier screen
assembly.
4. Push in gas control knob slightly and turn clockwise
to
“
oFF.
”
Do not force.
5. Replace the bottom louver if included, or re-install
barrier screen assembly.
THERMOCOUPLE
ELECTRODE
PILOT
THERMOPILE
GAS CONTROL KNOB SHOWN
IN "OFF" POSITION
REMOTE
OFF
ON
millivolt standing pilot lighting instrUctions
for YoUr safetY read before lighting
lighting instrUctions
to tUrn off gas to fireplace
Warning
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
Содержание MILLIVOLT DVCD32FP30
Страница 47: ...38712 2 0719 Page 47 7 Tuck Log G under Log C and onto pin of Log B LOG PLACEMENT for DVCD32 fireplaces...
Страница 48: ...38712 2 0719 Page 48 Log placement is complete LOG PLACEMENT for DVCD32 fireplaces...
Страница 57: ...38712 2 0719 Page 57 LOG PLACEMENT For DVCD36 fireplaces Log placement is complete...
Страница 67: ...38712 2 0719 Page 67 Log placement is complete LOG PLACEMENT for DVCD42 fireplaces...
Страница 93: ...38712 2 0719 Page 93 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 94: ...38712 2 0719 Page 94 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 95: ...38712 2 0719 Page 95 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...