38712-2-0719
Page 17
11”
(297 mm)
MIN.
9 1/8”
(232 mm)
MIN.
OUTSIDE THIMBLE ASSEMBLY
INSIDE THIMBLE ASSEMBLY
EXTERIOR
SHEAVING
figure 24
vent pipe clearance
Vertical, 90° Elbow with Horizontal Termination
3” (76mm)
MINIMUM CLEARANCE
TO COMBUSTIBLES
VENT CAP/
THIMBLE
WALL FIRESTOP
DVCD(32,36)
47 ½”
(121 cm)
TO BOTTOM
OF UNIT
DVCD42
49 ½”
(126 cm)
TO BOTTOM
OF UNIT
figure 25
horizontal only, straight out the back
“A”
PIPE LENGTH
VENT CAP
WALL FIRESTOP/
THIMBLE
“B”
dimensions (inches)
models
a
b
6
5-1/8 to 6-1/2
dvcd(32,36,42)
9
8-1/8 to 9-1/2
dvcd(32,36,42)
12
11-1/8 to 12-1/2
dvcd(32,36,42)
figure 26