Table 4. PWCRO-8000
Design
Vessels
Configuration
Single Pass
Vessel Array
1:1:1:1
Feed Water Source
City or Well Water
Vessel Quantity
4
Standard Recovery Rate
65%
Recovery with Concentrate Recycle
Up to 75%
Rejection and Flow Rates
Pumps
Nominal Salt Rejection %
98.5
Pump Type
Multi-Stage
Permeate Flow* gpm (lpm)
5.56 (21.13)
Motor HP (kw)
1.5 (1.10)
Minimum Feed Flow gpm (lpm)
8.56 (32.53)
RPM @ 60 (50Hz)
3450 (2900)
Maximum Feed Flow gpm (lpm)
14.00 (53.00)
Minimum Concentrate Flow gpm
(lpm)
3.00 (11.36)
Connections
Electrical
Feed inch
1" FNPT
Voltage
220V 60Hz 1PH
Permeate Inch
1/2" Tubing
Voltage Amp Draw
8.3
Concentrate Inch
1/2" Tubing
Membranes
System Dimensions
Membrane Per Vessel
1
L x W x H inch (cm)
25 x 25 x 60
(63.5 x 63.5 x
152.4)
Membrane Quantity
4
Weight lb. (kg)
400 (181.44)
Membrane Size
4" x 40" (4040)
Operating Limits
Maximum Feed Temperature °F (°C)
105 (40.96)
Maximum Free Chlor-
ine ppm
0
Minimum Feed Temperature °F (°C)
40 (4.44)
Maximum TDS ppm
2000
Maximum Ambient Temperature °F
(°C)
120 (48.89)
Maximum Hardness
gpg
< 1
Minimum Ambient Temperature °F
(°C)
35 (1.66)
Maximum pH (Continu-
ous)
11
Maximum Feed Pressure psi (bar)
85 (5.86)
Minimum pH (Continu-
ous)
3
Minimum Feed Pressure psi (bar)
35 (2.41)
Maximum pH (Cleaning
30 Min)
12
Maximum Operating Pressure psi
(bar)
150 (10.34)
Minimum pH (Cleaning
30 Min)
2
Maximum SDI Rating
< 3
Maximum Turbidity NTU
1
15
Содержание PWCRO
Страница 1: ...Penguin Water Whole House RO 224 PWCRO XXXX ...
Страница 11: ...20 UV Controller Monitors the UV light performance and bulb life 11 ...
Страница 30: ...30 ...
Страница 41: ...Membrane Flow Overview 41 ...
Страница 42: ...42 ...
Страница 43: ...43 ...
Страница 44: ...44 ...
Страница 47: ...System Flow Diagram 47 ...
Страница 48: ...48 ...
Страница 49: ...49 ...
Страница 50: ...50 ...
Страница 51: ...Typical System Layout 51 ...
Страница 56: ...Electrical Schematic 56 ...