System Connections, Requirements and Guidelines
PLUMBING
The membranes and high pressure pumps used on Whole House RO systems require a
continuous flow of water with a minimum feed pressure of 35 psi, not to exceed 105°F
while the system is running.
FEED WATER CONNECTION
1. Locate the 1" FNPT inlet connection on the sediment filter housing.
2. Attach the inlet piping to the 1" FNPT Filter housing inlet.
NOTE: FEED LINE MUST BE MINIMUM 3/4".
PERMEATE (PRODUCT WATER) CONNECTION
1. Locate the 1/2" tubing labeled permeate and attach to the bulkhead in the top of the
storage tank. Ensure that the permeate water can flow freely with no back pressure.
Back pressure can cause irreversible damage to the membrane elements.
NOTE: ALL PERMEATE PLUMBING SHOULD BE DONE WITH PLASTIC OR
STAINLESS STEEL. SOFT METALS WILL LEACH INTO THE WATER STREAM.
CPVC, PVC, PEX AND STAINLESS STEEL ARE THE MOST COMMONLY USED
MATERIAL.
CAUTION: THE PH OF THE REVERSE OSMOSIS PERMEATE WATER WILL TYPI-
CALLY BE 1-2 POINTS LOWER THAN THE FEED WATER PH. A LOW PH CAN
BE VERY AGGRESSIVE TO SOME PLUMBING MATERIALS SUCH AS COPPER
PIPING.