Low Pressure Switch
The low pressure switch shuts off the system when the feed water pressure drops below
15 PSI, preventing damage to the pump. The system restarts automatically when there is
a constant pressure of 30 PSI or more.
NOTE: If you notice the pressure fluctuating and the system cycling off and on,
turn the system off and ensure that proper feed flow and pressure are available to
the system.
Pump Throttle Valve
This valve is installed as a standard feature on the Whole House RO reverse osmosis
system. It provides an adjustment for pump pressure, which will vary as the required sys-
tem pressure changes. As the feed water temperature decreases, and / or the feed water
TDS increases, the system will require a higher operating pressure to produce the speci-
fied permeate flow. For example ; A system installed in Florida may provide the specified
permeate flow at 100 PSI ; however the same system installed in Maine with much colder
feed water may require 150 PSI to produce the same amount of permeate.
CAUTION! Never exceed 150 PSI