RO Start Delay
When the controller is placed in the operating mode or restarts from a shut down condi-
tion, the inlet valve will open and a 5 second time delay will start. During the delay, - - -
will show on the water quality display. After this delay, the RO pump will start. The water
quality display will now show the current water quality. The status lamp will show steady
green.
Pressure Fault
If the pressure fault input is active for 2 seconds, a pressure fault condition will occur.
This will cause the controller to shut down. PF will show on the water quality display and
the status lamp will flash red. To clear the pressure fault, press the power key twice.
Tank Full
If the tank full input is active for 5 seconds, the controller will shut down for a tank full con-
dition. The water quality display will show FUL. When the tank full condition clears, the
unit will restart after the selected restart delay.
Pretreat Lockout
If the pretreat lockout input is active for 2 seconds, the controller will shut down for a pre-
treat lockout condition. The water quality display will show PL. When the pretreat lockout
condition clears, the unit will restart.
Water Quality Display
The water quality display shows the current water quality when the controller is operating
normally and status messages when the controller is shut down. The water quality display
is 0 - 999 PPM. If the water quality is above 999, the display will show ^ ^ ^. If the water
quality is below the setpoint, the water quality lamp will be green. If the water quality is
above the setpoint, the water quality lamp will be red.
Water Quality Setpoint
The water quality setpoint can be adjusted from 0 - 999. If set to 999, the water quality
lamp will always remain green. To set the water quality setpoint, press the Setpoint key.
The display will alternate between the setpoint and SP. Use a small screwdriver to adjust
the SP adjustment to the desired setpoint value. Press the Setpoint key to return the dis-
play to the water quality display.
Calibration
To adjust the calibration of the water quality, measure the water with a meter calibrated to
a known standard. Using a small screwdriver, adjust the CAL adjustment to get the cor-
rect reading on the display.
55
Содержание PWCRO
Страница 1: ...Penguin Water Whole House RO 224 PWCRO XXXX ...
Страница 11: ...20 UV Controller Monitors the UV light performance and bulb life 11 ...
Страница 30: ...30 ...
Страница 41: ...Membrane Flow Overview 41 ...
Страница 42: ...42 ...
Страница 43: ...43 ...
Страница 44: ...44 ...
Страница 47: ...System Flow Diagram 47 ...
Страница 48: ...48 ...
Страница 49: ...49 ...
Страница 50: ...50 ...
Страница 51: ...Typical System Layout 51 ...
Страница 56: ...Electrical Schematic 56 ...