Proper Installation
This RO system must be properly installed and located in accordance with the Installation
Instructions before it is used or the warranty will be void.
•
Do not
install or store where it will be exposed to temperatures below freezing or ex-
posed to any type of weather. Water freezing in the system will break it. Do not attempt
to treat water over 100°F.
•
Do not
install in direct sunlight. Excessive sun or heat may cause distortion or other
damage to non-metallic parts.
• Properly ground to conform with all governing codes and ordinances. Use only
lead-
free solder and flux
for all sweat-solder connections, as required by state federal co-
des.
• Maximum allowable inlet water pressure is
125 psi.
If daytime pressure is over 80 psi,
night time pressure may exceed the maximum. Use a pressure reducing valve (PRV) to
reduce the pressure.
• RO membranes will degrade in the presence of chlorine or chloramines. In these condi-
tions, it is wise to consider purchasing a carbon filter system with a chlorine reducing
media. Contact Penguin Water for chlorine and chloramine removal equipment.