Maintenance
9
Maintenance table
9.2
EMG-MA-Ed23-Ed630-V2_EN_T.Nr.344029.docx
65
/ 74
9.2
Maintenance table
Table 58:
Maintenance log for ELDROclassic
®
thrusters
ELDROclassic
®
type
Serial no.
System ID
Classification accord-
ing to
section 3.1 (Table 1)
Low
requirements
Standard
Increased
requirements
❑
❑
❑
Subject of inspection
Test interval according to classification
Inspection
conducted
Inspection
passed
Evaluation /
measured values
Cleaning
as required
as required
as required
❑
❑
Test run
semestriellement
❑
❑
Visual check
Leakage
annually
annually
every 6 months
❑
❑
Pin joints
annually
annually
every 6 months
❑
❑
Terminal box cover
annually
annually
every 6 months
❑
❑
Firm seating of cable con-
nections
annually
annually
every 6 months
❑
❑
External damage
annually
annually
every 6 months
❑
❑
Function check
Motor function, operating
noises
annually
annually
❑
❑
max. stroke path
annually
annually
❑
❑
Tightness of terminal box
+ cable entry
annually
annually
❑
❑
Position indicator, signals,
adjustment
annually
annually
❑
❑
Extended inspection
Measurement of actuating
force
tous les 2-3 ans
❑
❑
Measurement of restoring
force
tous les 2-3 ans
❑
❑
Measurement of power
consumption
tous les 2-3 ans
❑
❑
Measurement of insula-
tion resistance
tous les 2-3 ans
❑
❑
Measurement of winding
resistance
tous les 2-3 ans
❑
❑
Содержание ELDROclassic Ed 121/12