Notes on operation
7
Check of operating conditions before commissioning
7.1
EMG-MA-Ed23-Ed630-V2_EN_T.Nr.344029.docx
57
/ 74
Never operate the ELDRO
®
device with defective or inoperable elec-
trical connections.
The terminal box must be kept closed at all times. Access may be
granted only to authorised personnel with corresponding training and
safety instruction.
In the event of failures on the energy supply, the ELDRO® device
must be shut off immediately.
7.1
Check of operating conditions before commissioning
NOTE
A bag (silica gel) is placed into the terminal box on delivery ex-fac-
tory, which serves to absorb any potentially arising moisture.
This bag (silica gel) must be removed before commissioning.
−
The ELDRO
®
device is assembled and connected according to the
specifications (
⇒
Section "Assembly and installation").
−
The permissible voltage and frequency tolerances are kept
(
⇒
Chapter "Technical data", Section "Voltage and frequency toler-
ances").
−
The ELDRO
®
device is filled with the operating liquid according to
the conditions of use (
⇒
Chapter "Technical data", Section "Ambi-
ent temperature and altitude of setup site") and according to the
model variant, and it is filled to the required level (
⇒
Chapter
"Maintenance", Section "Operating liquid").
−
The ELDRO
®
device is protected against contaminations
−
The mounting bolts on the thrust shackle and the base mounting
are secured against accidental movements (e.g. by means of
safety splinter pins).
−
The axes are arranged in parallel to each other.