Maintenance
9
Maintenance work
9.1
EMG-MA-Ed23-Ed630-V2_EN_T.Nr.344029.docx
63
/ 74
9.1.2
Check of the operation liquid
WARNUNG
Hot operating liquid
Risk of burns caused by hot oil vapours when opening the filler
screw while the device has operating temperature.
– Operating liquid may only be checked, refilled or drained in
the shut-off and cold condition.
– The ELDRO
®
device may only be opened at a maximum tem-
perature of 40°C.
▪
NOTE
If the fill level is too low, the device will not develop the full lifting
force.
If it is filled too much, an impermissibly high device pressure is cre-
ated.
The ELDRO
®
devices are filled for correct operation when the operat-
ing liquid level in the vertical upright position and with the lifting rod
retracted reaches the lower edge within the filler opening.
Notice the information on disassembly if the ELDRO
®
device is
not installed in vertical upright position (
⇒
Chapter "Disassem-
bly").
▪
Bring the ELDRO
®
device into a vertical position.
▪
Remove the filler screw from the filler neck.
▪
Check the fill level depending on the ELDRO
®
type and refill if nec-
essary.
Figure 16:
Fill level of operating liquid
1 Filler neck
2 Lower edge of filler neck (fill level for operating liquid)