9
Maintenance
9.1
Maintenance work
62
/ 74
EMG-MA-Ed23-Ed630-V2_EN_T.Nr.344029.docx
9.1.1
Operating liquid
ELDRO
®
devices are delivered ex-factory with an operating liquid that
is dependent on the conditions of use and the desired model variant
of the device. An operating liquid sort is specified on the rating plate.
NOTE
The safety datasheet of the oil manufacturer must be observed.
Always the same sort as the one already in the device must be
chosen for refilling.
Table 57:
Fill quantities of operating liquid
ELDRO
®
-type
Fill quantity in litres
ELDRO
®
-type
Fill quantity in litres
Ed 23/5
1.6
Ed 301/15
12.1
Ed 30/5
1.9
Ed 350/20
12.1
Ed 50/6
4.2
Ed 400/6
9.2
Ed 80/6
4.2
Ed 400/8
9.2
Ed 121/6
9.4
Ed 400/10
9.2
Ed 185/6
9.2
Ed 400/12
9.2
Ed 201/6
9.5
Ed 450/8
9.2
Ed 301/6
9.2
Ed 450/12
9.2
Ed 50/12
5.5
Ed 450/20
1.1
Ed 80/12
5.5
Ed 500/8
12.1
Ed 121/12
9.4
Ed 500/10
12.1
Ed 201/12
9.4
Ed 630/8
12
Ed 301/12
9.2
Ed 630/9
12
Ed 185/16
9.4
Ed 630/10
12
ELDRO
®
devices are filled on delivery for the temperature range
from
-25°C to +50°C with the operating liquid (hydraulic oil) Shell Morlina
10 oil of class HL10 DIN 51524. For other temperature ranges, spe-
cial operating liquids are required (inquire with the manufacturer).