SI-Safety Installation & Operating Manual
71
Issue Number: 1
S
Devi
Te
safety
Inst
all
SI-Safety module
S
Mai
nte
Te
SI
error t
En
Va
Enc
oder
Am
endment
Index
9.3
Fault list for SI-Safety
Fault code
F 1001
Fault message
Configuration data were not loaded into the monitoring device
properly
Cause
Connection fault when loading the program to the monitoring
device
Remedial action
Reload the configuration data, then switch the module on/off.
Fault code
F 1003
Fault message
Configuration data for the module is invalid
Cause
Module configured with incorrect version of software for the
programming user interface
Remedial action
Configure the module with the authorized version of the
programming user interface, then switch the module on/off
Fault code
F 1007
Fault message
Device was not programmed with the correct programming user
interface
Cause
Program or configuration data were loaded onto the device with
the wrong programming user interface
Remedial action
Check module version and reconfigure using a valid
programming user interface. Then switch the device on/off
Fault code
F 1307
Fault message
Fault when deleting configuration data from flash memory
Fault code
F 1311 / F1312
Fault message
Internal fault – please contact the manufacturer
Fault code
F 1314
Fault message
Internal fault – please contact the manufacturer
Fault code
F 1330
Fault message
Internal fault – please contact the manufacturer
Fault code
F 1401 / F 1402
Fault message
Internal fault – please contact the manufacturer
Fault code
F 1403 / F 1404
Fault message
CRC of configuration data invalid
Cause
Configuration data were transmitted incorrectly
Remedial action
Retransmit the configuration data
Содержание unidrive m