76
SI-Safety Installation & Operating Manual
Issue Number: 1
Fault code
F 3306
Fault message
Plausibility fault, position changeover
Cause
During position changeover, SOS, SLI or SDI is continuously
enabled
Remedial action
Check SOS activation
Check SLI activation
SDI activation (only when monitoring by position)
Fault code
F 3316
Fault message
Fault in sensor alignment
Cause
Defective position triggering by System A
Remedial action
Check the sensor configuration
Switch the device on/off
Fault code
F 3604
Fault message
Defective testing of output STO.1 (static test)
Cause
Output switch status defective
Remedial action
Switch the device on/off
Fault code
F 3605
Fault message
Defective testing of MainSwitch (dynamic test)
Cause
Output switch status defective
Remedial action
Switch the device on/off
Fault code
F 3609
Fault message
Defective switching of output SBC1 (dynamic test)
Cause
Output switch status defective
Remedial action
Switch the device on/off
Fault code
F 3610
Fault message
Defective testing of MainSwitch (static test)
Cause
Output switch status defective
Remedial action
Switch the device on/off
Fault code
F 3611
Fault message
Defective switching of output STO (dynamic test)
Cause
Output switch status defective
Remedial action
Switch the device on/off
Содержание unidrive m