5.2
Power module replacement
Expected power module life is 10 years at reference conditions.
(1)
When power module replacement is required, remove the power module cover on the field
terminal side and remove the power module. Replace the power module (part number
00753-9220-0001) and replace the cover. Tighten to specification and verify operation.
Handling considerations
Each power module with the wireless unit contains two “C” size primary lithium/thionyl chloride
batteries. Each battery contains approximately 2.5 grams of lithium, for a total of 5 grams in
each pack. Under normal conditions, the battery materials are self-contained and are not
reactive as long as the batteries and the power module integrity are maintained. Care should be
taken to prevent thermal, electrical or mechanical damage. Contacts should be protected to
prevent premature discharge.
Use caution when handling the Power Module, it may damaged if dropped from heights in
excess of 20 feet.
Battery hazards remain when cells are discharged.
Power modules should be stored in a clean and dry area. For maximum power module life,
storage temperature should not exceed 30 °C.
Environmental considerations
As with any battery, local environmental rules and regulations should be consulted for proper
management of spent batteries. If no specific requirements exist, recycling through a qualified
recycler is encouraged. Consult the materials safety data sheet for battery specific information.
Shipping considerations
The unit is shipped to you without the power module installed. Unless specifically instructed to
do otherwise, remove the power module from the unit prior to shipping.
The unit was shipped to you without the power module installed. Remove the power module
prior to shipping.
Each power module contains two “C” size primary lithium batteries. Primary lithium batteries
are regulated in transportation by the U. S. Department of Transportation, and are also covered
by IATA (International Air Transport Association), ICAO (International Civil Aviation
Organization), and ARD (European Ground Transportation of Dangerous Goods). It is the
responsibility of the shipper to ensure compliance with these or any other local requirements.
Consult current regulations and requirements before shipping.
1.
Reference conditions are 70 °F (21 °C), transmit rate of once per minute, and routing data for three additional network devices.
Содержание Rosemount X-well 648
Страница 2: ......
Страница 6: ...vi Reference Manual 00809 0200 4648 Rev BB Title Page July 2016 Title Page ...
Страница 10: ...4 Reference Manual 00809 0200 4648 Rev BB Contents July 2016 Contents ...
Страница 12: ...2 Reference Manual 00809 0200 4648 Rev BB Introduction July 2016 Introduction ...
Страница 36: ...26 Reference Manual 00809 0200 4648 Rev BB Configuration July 2016 Configuration ...
Страница 52: ...42 Reference Manual 00809 0200 4648 Rev BB Commissioning July 2016 Commissioning ...
Страница 62: ...52 Reference Manual 00809 0200 4648 Rev BB Operation and Maintenance July 2016 Operation and Maintenance ...
Страница 66: ...56 Reference Manual 00809 0200 4648 Rev BB Troubleshooting July 2016 Troubleshooting ...
Страница 89: ......