Figure 3-4: Side-to-Side and Side-to-Bottom Chambers
'
&
&
(
$
$
%
A. Dimension A
B. Dimension B
C. Dimension CC
D. Side-to-side chamber
E. Side-to-bottom chamber
When mounting in a Rosemount chamber, see
for information on probe length
determination.
Table 3-4: Probe Length Determination for Rosemount CMB Chambers
Chamber type
Probe length
Side-to-side chamber
A + CC + B - 80 mm
Side-to-bottom chamber
A + CC - 80 mm
Use a centering disc the same diameter as the chamber if the probe length >3.3 ft. (1 m).
See
Existing chamber
A Rosemount 3308 Series Transmitter is the perfect replacement in an existing displacer
chamber. Proprietary flanges are offered, enabling use of existing chambers to make
installation easy.
Reference Manual
Installation
00809-0100-4308
February 2020
Reference Manual
29
Содержание Rosemount 3308A
Страница 8: ...Contents Reference Manual February 2020 00809 0100 4308 viii Rosemount 3308 Series ...
Страница 10: ...Introduction Reference Manual February 2020 00809 0100 4308 10 Rosemount 3308 Series ...
Страница 22: ...Transmitter overview Reference Manual February 2020 00809 0100 4308 22 Rosemount 3308 Series ...
Страница 74: ...Installation Reference Manual February 2020 00809 0100 4308 74 Rosemount 3308 Series ...
Страница 96: ...Configuration Reference Manual February 2020 00809 0100 4308 96 Rosemount 3308 Series ...
Страница 194: ...Product Certifications Reference Manual February 2020 00809 0100 4308 194 Rosemount 3308 Series ...
Страница 222: ...Configuration parameters Reference Manual February 2020 00809 0100 4308 222 Rosemount 3308 Series ...