Table 6-3: Configuration Error Details (D:)
(continued)
Message
Description
Recommended actions
User Defined Alert configuration is
invalid
User Defined Alerts will not be raised
as expected because of invalid
configuration.
•
Check entered limit and deadband
values in relation to the selected
variable.
Signal Quality Alert configuration is
invalid
Signal Quality Alerts will not be raised
as expected because of invalid
configuration.
•
Check entered limit and deadband
values regarding their range [0.1 –
10.0] and mutual relationship.
No user configuration errors detected
No user configuration errors detected. N/A
Table 6-4: Maintenance Alerts (M:)
Message
Description
Recommended actions
Supply Voltage Low
The supply voltage is low and may
affect Device Operation.
•
Replace the Power Module, see
Electronics Temperature Out of Limits The temperature of the electronics
board has exceeded the transmitter’s
operating range.
1. Verify that ambient temperature
is within the operating range.
2. Restart the device.
3. Remote mount the transmitter
head away from the process and
environmental conditions.
4. If the condition persists, replace
the device.
Level Measurement Lost
No valid Level reading. Reasons may
be multiple:
•
No valid surface echo peak in the
measuring range.
•
Incorrect transmitter
configuration.
1. Analyze the Echo Curve for
reason and check device
configuration, especially
thresholds, Near Zone, Maximum
Level Rate and settings on the
Lost Measurement tab in the
Alert Setup.
2. Check device physical installation
(for instance probe
contamination).
3. Restart level measurement.
4. Restore default settings and
reconfigure the device.
5. If the condition persists, replace
the device.
Reference Manual
Service and troubleshooting
00809-0100-4308
February 2020
Reference Manual
111
Содержание Rosemount 3308A
Страница 8: ...Contents Reference Manual February 2020 00809 0100 4308 viii Rosemount 3308 Series ...
Страница 10: ...Introduction Reference Manual February 2020 00809 0100 4308 10 Rosemount 3308 Series ...
Страница 22: ...Transmitter overview Reference Manual February 2020 00809 0100 4308 22 Rosemount 3308 Series ...
Страница 74: ...Installation Reference Manual February 2020 00809 0100 4308 74 Rosemount 3308 Series ...
Страница 96: ...Configuration Reference Manual February 2020 00809 0100 4308 96 Rosemount 3308 Series ...
Страница 194: ...Product Certifications Reference Manual February 2020 00809 0100 4308 194 Rosemount 3308 Series ...
Страница 222: ...Configuration parameters Reference Manual February 2020 00809 0100 4308 222 Rosemount 3308 Series ...