Figure A-6: Accuracy over Measuring Range for Coaxial Probe
±0.12 in.
(3 mm)
±1.18 in.
(30 mm)
±0.12 in.
(3 mm)
±1.18 in.
(30 mm)
±0.2 in.
(5 mm)
±1.18 in.
(30 mm)
±0.2 in.
(5 mm)
±1.18 in.
(30 mm)
5.5 in. (14 cm)
5.5 in. (14 cm)
11.8 in. (30 cm)
13.0 in. (33 cm)
5.1 in. (13 cm)
7.1 in. (18 cm)
5.1 in. (13 cm)
7.1 in. (18 cm)
2.0 in. (5 cm)
2.0 in.
(5 cm)
2.0 in. (5 cm)
2.0 in.
(5 cm)
1.2 in. (3 cm)
1.2 in. (3 cm)
E
E
E
E
C
D
C
D
A
B
F
A. High performance (profile code U)
B. Standard (profile code S)
C. Water (DC = 80)
D. Oil (DC = 2.2)
E. Accuracy
F. Blind Zone
A.2
Functional specifications
A.2.1
General
Field of application
Liquids and semi-liquids level or liquid/liquid interfaces
•
3308Axx1... for level or submerged probe interface measurement
•
3308Axx2... for level and interface measurement
Measurement principle
Time Domain Reflectometry (TDR)
Related information
Microwave output power
Nominal 10 µw, Max <20 mW
Reference Manual
Specifications and reference data
00809-0100-4308
February 2020
Reference Manual
149
Содержание Rosemount 3308A
Страница 8: ...Contents Reference Manual February 2020 00809 0100 4308 viii Rosemount 3308 Series ...
Страница 10: ...Introduction Reference Manual February 2020 00809 0100 4308 10 Rosemount 3308 Series ...
Страница 22: ...Transmitter overview Reference Manual February 2020 00809 0100 4308 22 Rosemount 3308 Series ...
Страница 74: ...Installation Reference Manual February 2020 00809 0100 4308 74 Rosemount 3308 Series ...
Страница 96: ...Configuration Reference Manual February 2020 00809 0100 4308 96 Rosemount 3308 Series ...
Страница 194: ...Product Certifications Reference Manual February 2020 00809 0100 4308 194 Rosemount 3308 Series ...
Страница 222: ...Configuration parameters Reference Manual February 2020 00809 0100 4308 222 Rosemount 3308 Series ...