S600+ Instruction Manual
4-24
I/O
Revised July-2017
4.2.6 Jumper Settings
The boldface entries in the Position column on
Table 4-22
are the
default configuration settings. They may not apply to your specific
configuration.
Table 4-22. Prover Module Jumper Settings
Jumper
Position
Descriptions
Flash
LK1
ON
Write Enable
OFF
Write Protected
Node Address
(see Table 4-23)
LK2
ON
OFF
Multiplexed mode (MUX)
LK11
ON
OFF
Multiplexed mode (MUX)
MUX Address:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
LK3
●
●
LK4
●
●
LK5
●
●
LK6
●
●
LK7
●
●
LK8
●
●
LK9
●
●
LK10
1-2
●
●
●
●
●
●
●
2-3
●
●
●
●
●
●
●
Altera Voltage
LK12
1-2
3.465V
2-3
5V - Vcc
Raw Pulse Output Mode
(currently not supported)
LK13/14
1-2
RS-422 differential driver
2-3
Open collector
Raw Pulse Input #3
– Line Determination
LK15/16
ON
Line determination resistors connected: +ve pulled up to Vcc and
–ve down to 0V
OFF
Lines undetermined
Table 4-23. Node Addressing: Communications Mode Selection
Mode
Link 2
Link 11
Link 3-10
Point-to-point
ON
OFF
IGNORED
Multi-dropped
ON
ON
IGNORED
Multiplexed (MUX)
OFF
OFF
ADDRESS
Содержание FloBoss S600+
Страница 55: ...S600 Instruction Manual Revised July 2017 I O 4 17 Figure 4 20 Prover Module P154 Figure 4 21 Prover Module ...
Страница 66: ...S600 Instruction Manual 4 28 I O Revised July 2017 This page is intentionally left blank ...
Страница 84: ...S600 Instruction Manual 5 18 Front Panel Revised July 2017 This page is intentionally left blank ...
Страница 92: ...S600 Instruction Manual 6 8 Webserver Access Revised July 2017 This page is intentionally left blank ...
Страница 114: ...S600 Instruction Manual A 8 Glossary Revised July 2017 This page is intentionally left blank ...
Страница 122: ...S600 Instruction Manual B 8 Front Panel Navigation Revised July 2017 This page is intentionally left blank ...
Страница 150: ...S600 Instruction Manual C 28 Chromatographs Revised July 2017 2350 USA 2551 USA ...