Maintenance and Troubleshooting Manual
Section 3: Meter maintenance
3-9000-764 Rev F
December 2017
Acquisition Module replacement
49
10.
When you have completed attaching the transducer wire terminal blocks and the
Acquisition cable terminal block to the Acquisition Module, check the Base Enclosure
O-ring and reinstall if necessary.
11.
Reattach the Transmitter Electronics Enclosure to the Base Enclosure with the two hex
head bolts and lock washers. Tighten bolts with a 6mm Allen wrench.
12.
Retighten or reattach the conduit to the Transmitter Electronics Enclosure using a
crescent wrench or channel lock pliers.
13.
If required, install the security seal wire into and through one of the two holes in the
end cap. Choose holes that minimize counterclockwise rotation of the end cap when
the security wire is taut (maximum wire diameter.078 inch; 2.0mm) (
14.
Adjust the security wire, removing all slack and thread into the lead seal.
15.
Cut wire ends to remove excess wire.
16.
If required, apply conduit sealing compound according to manufacturer’s recommen-
dations.
17.
Apply power to the meter.
18.
This completes the Acquisition Module replacement procedure.
19.
If you encounter problems with this procedure, see the Daniel Customer Service
contact information on the back cover of this manual.