Maintenance and Troubleshooting Manual
Section 2: Troubleshooting
3-9000-764 Rev F
December 2017
Meter maintenance
27
Meter Components
Visual Inspection
Action(s)
Security seals
•
Endcap seals
•
Endcaps latches
•
Transmitter Electronics Enclosure
•
Base Enclosure
•
Shroud seals
•
Only authorized personnel may
remove security seals. Follow your
standard operating procedure to
report seals that have been tampered
with or removed and replace the seals
per instructions in Section 3.6.8 in the
Installation Manual (3-9000-765).
External ground wiring
•
Transmitter Electronics Enclosure
ground lug
•
Inspect ground lug wiring and make
sure the wiring is tightly secured.
Conduit seals
•
Transmitter Electronics Enclosure
•
Inspect the conduit sealant and follow
your standard operating procedure to
report tampering with the conduit
sealant.
•
Your operating procedures may
require a certified electrician and
company witness to reseal the
conduit.
Flanges
•
Inspect for leaks
•
Inspect flange stabilizers
•
Perform leak tests on flanges
•
Ensure flange stabilizers are installed.
CRUSHING HAZARD
Do not remove flange stabilizers.
Attempting to do so may allow the meter to roll, resulting in serious injury or equipment damage.