MENU 9: LOGIC FUNCTIONS, MOTORISED POT AND BINARY SUM
CONTROL TECHNIQUES
3854 en - 03.2008 / b
: Motorised pot bipolar select
Adjustment range : 0 or 1
Factory setting
: 0
0 (Positive) (Pos): The up/down pot reference is limited to
positive values (0 to 100.0%).
1 (Bipolar) (biPo.): The up/down pot reference can change
from -100% to +100%.
: Motorised pot rate
Adjustment range : 0 to 250 s
Factory setting
: 20 s
This parameter defines the time it takes for the up/down pot
reference to change from 0 to 100.0%.
It will take twice as long to change from -100.0% to +100.0%.
Defines the potentiometer sensitivity.
: Motorised pot scale factor
Adjustment range : 0 to 2.50
Factory setting
: 1.00
The maximum value of the up/down pot reference
automatically takes the maximum value of the parameter to
which it is assigned.
This parameter can therefore be used to adapt the maximum
value of the up/down pot reference to the maximum value
required by the application.
Example:
- The up/down reference is addressed to a preset reference.
- The maximum value of a preset reference is 32000 rpm.
- We want the maximum value of the up/down reference to
correspond to 1500 rpm.
==>
9.24
: Motorised pot destination
Adjustment range :
0.00
to
21.51
Factory setting
:
0.00
This parameter is used to define the numerical parameter
which the up/down pot reference will control.
Example: The up/down pot reference acts as a speed
reference. The up/down pot reference can be sent to a preset
reference.
==>
9.25
=
1.21
.
: Motorised pot up
Adjustment range : 0 or 1
0 (Disabled) (OFF)
1 (Enabled) (On)
A digital input must be assigned to this parameter for
controlling the motorised pot up function.
: Motorised pot down
Adjustment range : 0 or 1
0 (Disabled) (OFF)
1 (Enabled) (On)
A digital input must be assigned to this parameter for
controlling the motorised pot down function.
: Motorised pot reset
Adjustment range : 0 or 1
Factory setting
: 0
0 (Disabled) (No): Reset inactive.
1 (Enabled) (RSEt): The motorised pot reference is reset to
zero.
to
: Binary sum inputs
Adjustment range : 0 or 1
Used to modify remotely, using a combination of digital
inputs, a parameter whose selection includes more than two
possible options.
0 (Disabled) (OFF)
1 (Enabled) (On)
9.29
: Binary sum ones input.
9.30
: Binary sum twos input.
9.31
: Binary sum fours input.
: Binary sum output
Adjustment range : 0 to 39
Used to read the decimal value of the binary sum output.
: Binary sum destination
Adjustment range :
0.00
to
21.51
Factory setting
:
0.00
Used to define the parameter that the binary sum will control.
Any bit, switch or numerical type parameter can be assigned
to the binary sum.
: Binary sum output offset
Adjustment range : 0 to 32
Factory setting
: 0
Used to add an offset to the binary sum output.
to
: Not used
and
:Not used
and
:Not used
9.22
9.23
9.24
= =
0.05
1500
32000
9.25
9.26
9.27
9.31
9.30
9.29
Decimal conversion
0
0
0
0
0
0
1
1
0
1
0
2
0
1
1
3
1
0
0
4
1
0
1
5
1
1
0
6
1
1
1
7
9.28
9.29
9.31
9.32
9.33
9.34
9.35
9.59
9.62
9.63
9.72
9.73
Содержание Commander SX
Страница 1: ...Part Number Commander SX IP66 Nema 4X variable speed drive Advanced user Guide 3854 en 03 2008 b ...
Страница 139: ......
Страница 140: ......