MENU 21: OPERATING PARAMETERS FOR A SECOND MOTOR
CONTROL TECHNIQUES
3854 en - 03.2008 / b
20 - MENU 21: OPERATING PARAMETERS FOR A SECOND MOTOR
20.1 - List of parameters in Menu 21
: Function not available.
Parameter
Name
Type
Adjustment range
Factory setting
User
setting
21.01
Motor 2 maximum reference clamp
R-W
0 to 32000 rpm
Eur: 1500 rpm
USA: 1800 rpm
21.02
Motor 2 minimum reference clamp
R-W/P
0 to 32000 rpm
0
21.03
Motor 2 reference selector
R-W
0 to 4
0
21.04
Motor 2 acceleration rate
R-W
0 to 600.0 s/1000 rpm
3.0 s/1000 rpm
21.05
Motor 2 deceleration rate
R-W
0 to 600.0 s/1000 rpm
5.0 s/1000 rpm
21.06
Motor 2 rated frequency
R-W
0 to 400.0 Hz
Eur: 50.0 Hz
USA: 60.0 Hz
21.07
Motor 2 rated current
R-W
0 to drive rated current
(A)
Motor rated
current (A)
corresponding to
the drive rating
21.08
Motor 2 rated speed
R-W
0 to 9999 rpm
Motor rated speed
(rpm)
corresponding to
the drive rating
21.09
Motor 2 rated voltage
R-W
0 to 480 V
Eur L: 200 V
USA L: 230 V
Eur H: 400 V
USA H: 460 V
21.10
Motor 2 rated power factor (cos
ϕ
)
R-W
0 to 1.00
0.85
21.11
Motor 2 number of poles
R-W
0 to 4
0
21.12
Motor 2 stator resistance
R-W
0 to 32.000
Ω
0
21.13
Motor 2 voltage offset
RO
0 to 25.5 V
-
21.14
Motor 2 inductance
R-W
0 to 3200.0 mH
0
21.15
Motor 2 parameters active
RO/P
0 or 1
-
21.16
Not used
to
21.23
21.24
Motor 2 stator inductance L
S
R-W
0 to 3200.0 mH
150.0 mH
21.25
Not used
to
21.29
21.30
Motor volts per 1000 rpm (Ke)
R-W
0 to 10000 V
98 V
21.31
Not used
to
21.50
21.51
q axis inductance
R-W
0 to 999.9 mH
150.0 mH