background image

 

 

14 

 

6.

 

OPERATION OF THE DEVICE 

 

Important! After connecting the EMERALD device it is necessary to familiarize yourself 

with the operating rules.

 

 

Fig. 14. Internal elements of the EMERALD device 

1 — inlet of unpurified cold tap water; 2 - output of purified antioxidant water; 3 - water flow 
regulator; 4 - catalytic filter; 5 - electrokinetic filter; 6 - electrochemical module (the main 
component of the EMERALD device); 7- monitoring and control unit; 8- hydraulic input for 
citric acid washing solution; 9 – flushing mode on / off button; 10 - plug for flushing device 
connection; 11- flushing device.. 

 

Important!  Do  not  use  for  food  or  drinking  purposes  the  first  30  liters  of  the  purified 

water  immediately  after  connecting  the  device.  In  the  case  of  prolonged  downtime  of  the 
device (more than 1 day) then the first 30 liters of purified water shall also be discharged. 

When you turn on the EMERALD for the first time it is necessary to adjust the speed of 

the purified water flow (see the “Setting the Flow of Water” section). 

The  device  is  intended  for  the  purification  and  electrical  treatment  ONLY  OF  COLD 

WATER  FROM  CENTRALIZED  WATER  SUPPLY  SYSTEMS!  When  the  OPERATION 
mode of drinking water is activated then it is not allowed using warm or hot water through 
the device as this may damage it. 

Do  not  use  the  device  for  purification  of  microbiologically  unsafe  water  or  water  of 

unknown origin without the proper preliminary filtration and disinfection. 

Содержание Home 3

Страница 1: ...PASSPORT AND OPERATION MANUAL EMERALD HOME 3 FOR PURIFICATION AND ELECTRIAL TREATMENT OF FRESH WATER...

Страница 2: ...tion 12 Connection of the device to the electric network 13 6 OPERATION OF THE DEVICE 14 Supply of tap water 15 Water flow rate adjustment 15 Operation of the device with the connection under the sink...

Страница 3: ...e nature Reproducing the most complex natural processes of water purification and treatment has become possible due to the creation of highly reliable electrochemical modules which are the main elemen...

Страница 4: ...ious to use for washing in the form of ice cubes to wipe the face or spray the water in the form of aerosol to moisturize the skin Moisturizing masks with the use of antioxidant water will have the sp...

Страница 5: ...safe The water treatment processes are identical to natural ones but they are accelerated tens of thousands of times due to the use of the latest technologies and elec trochemical modules The catalyti...

Страница 6: ...ified from free chlorine and chlororganic compounds u Improves the taste of water and eliminates the unpleasant odors due to the anodic removal of phenols and hydrogen sulfide Fig 3 Cathodic chamber o...

Страница 7: ...alination of water u Do not disassemble or repair the device by yourself Contact the authorized service center In order to reduce the risk of fire or electric shock it is strongly recommended not to d...

Страница 8: ...not replace the plug by yourself u Regular maintenance of the EMERALD with flushing of the filter elements and the electro chemical module is required see the section MAINTENANCE OF THE DEVICE u Do n...

Страница 9: ...ith the basic principles of connecting the white tube with fittings described in the section General rules for handling quick detachable joints such as John Guest The fixed connection of the EMERALD r...

Страница 10: ...til it stops in the hole of the fitting If the connection is right then the tube enters the fitting hole by 15 18 mm u Check the reliability of tube connection by countermotion of the tube At the coun...

Страница 11: ...ball valve for supplying water to the device 6 hydraulic inlet for flushing the device with citric acid 7 power source adapter 8 clean water tap 9 electric plug for connecting a flushing device 10 pow...

Страница 12: ...tightly on the tee fitting and tighten the nut u Check the reliability of all connections Attention During the connection of these elements do not overtighten the connections It can lead to the fractu...

Страница 13: ...the plastic tube pass it through the clamping nut put a plastic sleeve on the connecting end of the tube and insert a plastic piston into the tube then insert the tube into the shank of the tap and ti...

Страница 14: ...power supply into the power socket of the EMERALD device in the upper left corner of the side of the case Important It is forbidden to disconnect a working device in OPERATION or FLUSHING mode from t...

Страница 15: ...purposes the first 30 liters of the purified water immediately after connecting the device In the case of prolonged downtime of the device more than 1 day then the first 30 liters of purified water s...

Страница 16: ...the water pressure in the water supply system For high quality purification and electrical treatment the water flow through the device should be no more than 1 liter min 60 liters hour If the flow rat...

Страница 17: ...k all the most important parameters of the EMERALD device The multifunctional indicator allows one to evaluate u The resource of the device after which it is necessary to flush the de vice see Section...

Страница 18: ...less than 8 hours then when it is turned on the green LED will not be flashing which will indicate that water is not required to be discharged from the device u After 8 hours of working in the OPERATI...

Страница 19: ...4 months or after 1 200 liters of the purified water whichever comes earlier The EMERALD automatically monitors the volume of purified water and it notifies you about the need for flushing u After 8...

Страница 20: ...carried out in accordance with Fig 18 in the following order Preparation of citric acid washing solution To carry out the flushing procedure for the EMERALD it is necessary to prepare 1 one liter of...

Страница 21: ...alled on the flat stable surface near the sink on the tabletop or on the floor Fig 19 Sequence of connection of the flushing device in FLUSHING mode Press the FLUSH button 10 to activate the flushing...

Страница 22: ...ists of the following steps u RETENTION stage Retention of the washing solution of citric acid in the device for 30 minutes u After 30 minutes have elapsed the LED will blink blue indicating that the...

Страница 23: ...nctions that could inter rupt the course of the FLUSHING mode please repeat the FLUSHING procedure before using the device If faults are detected during the FLUSHING mode it is necessary to additional...

Страница 24: ...necessary pressure in the water supply line see Table 5 2 Adjust the water flow rate correctly see the Water flow rate section and Fig 16 3 Flush the device with citric acid solution see the device Ma...

Страница 25: ...ication corrective actions or maintenance performed by any person other than the authorized representative of the warranty service and maintenance service of the manufacturer or official trading partn...

Страница 26: ...s for refusing by the representative of the manufacturer to connect the device as well as provide with the service and warranty service In the case of self installation and service of the device the m...

Страница 27: ...water temperature 1 30 Water supply line pressure MPa 0 1 0 4 Total mineralization of supplied tap water ppm 100 350 pH of supplied tap water 6 9 Efficiency of anodic oxidation of bivalent iron ions w...

Страница 28: ...e tube made of food grade plastic 1 8 Specification and operating manual 1 Add 1 Additional diverter for the tap with a set of nozzles for alternative connection of the EMERALD above the sink to the t...

Страница 29: ...acture the EMERALD as well as to provide them with service and warranty service EMERALD ECOTECHNOLOGIES LLC has the exclusive right to transfer to its official trading partners all the necessary power...

Страница 30: ...29 APPENDIX No 1 CERTIFICATES 1 CERTIFICATE OF CONFORMITY OF QUALITY MANAGEMENT SYSTEM REQUIREMENTS GOST R ISO 9001 2015 ISO 9001 2015 2 CERTIFICATE OF CONFORMITY OF THE EAC CUSTOMS UNION...

Страница 31: ...30 1 EXPERTS REPORT ISSUED BY ROSPOTREBNADZOR...

Страница 32: ...31 2 VOLUNTARY CERTIFICATE OF COMPLIANCE WITH GOST R 3 DECLARATION OF COMPLIANCE WITH EAC OF THE CUSTOMS UNION...

Страница 33: ...liability and tightness of all connections Connecting tubes to the diverter Unscrew the nuts on both divertor fittings and put these nuts on the connecting tubes Fit the tubes tightly on both diverter...

Отзывы: