 SVR-I1U-1304 Server Installation and

Maintenance Guide

P/N 300-013-263
REV 02

May, 2013

This document describes installation and maintenance procedures for the SVR-I1U-1304
server. This server has slots for four 3.5-inch drive assemblies. Some server components
are replaceable as field replaceable units (FRUs). Refer to your product documentation for
information on which components are FRUs. Before attempting to perform hardware service
procedures, review your service contract because replacement of some server components
by unauthorized personnel may void service warranties.
Topics include:

u

Technical information and requirements

.................................................................... 2

u

Installing the server in a cabinet

.................................................................................3

u

Maintaining the server

............................................................................................. 14

u

Handling field replaceable units (FRUs)

....................................................................14

u

Replacing a disk drive assembly

.............................................................................. 15

u

Replacing the server

.................................................................................................18

u

Removing the slide rails from the cabinet

.................................................................27

Содержание SVR-I1U-1304

Страница 1: ...duct documentation for information on which components are FRUs Before attempting to perform hardware service procedures review your service contract because replacement of some server components by u...

Страница 2: ...tion Requirement Description AC line voltage 90 264 V AC autoranging 47 63 Hz Power consumption operating maximum 420 VA 412 W maximum fully configured Heat dissipation 14 832 x 105 J hr 1406 BTU hr m...

Страница 3: ...feet the maximum operating temperature is de rated 1 F 550 ft Shipping and storage requirements Table 4 Shipping and storage requirements Requirement Description Ambient temperature 40 C to 65 C 40 F...

Страница 4: ...10 Power up the server 4 EMC SVR I1U 1304 Server Installation and Maintenance Guide...

Страница 5: ...ips pan head 8 32 x 0 35 in screws Stabilize the server and rail mounting 1U bezel application specific CL4887 Covers front of server in cabinet You need a 2 Phillips head screwdriver to complete the...

Страница 6: ...the rail end and hold the tab in 3 Rotate the alignment post assembly either clockwise to switch from round posts to square posts or counter clockwise to switch from square posts to round posts until...

Страница 7: ...883 3 1 2 Attaching the inner rails to the server Attach an inner rail to each side of the server by performing the procedure that follows for each rail Refer to Figure 3 on page 8 while performing th...

Страница 8: ...ontains a right and a left slide rail Install each slide rail in the cabinet using the procedure that follows Procedure 1 From the front of the cabinet align rail alignment posts with the rear channel...

Страница 9: ...go securely into the holes on the front channel Figure 5 on page 9 An audible click indicates that the connection is secure Figure 5 Inserting rail alignment posts into front channel holes CL5091 3 S...

Страница 10: ...rt werden Zur Vermeidung von k rperlichen Verletzungen und oder der Besch digung des Ger tes bitte das Geh use nicht ohne die Hilfe einer zweiten Person anheben und einbauen Il contenitore pesante e d...

Страница 11: ...ty Figure 8 on page 11 shows the inner rail without the server attached Figure 8 Aligning the inner rail with white plastic guide block CL5093 3 Slide the server into the cabinet so the inner rails ex...

Страница 12: ...slide rails are engaged and locked 5 On the outside of each rail assembly slide the blue disconnect tab forward to unlock the server and push the server completely into the cabinet Figure 10 on page...

Страница 13: ...ation specific and may not appear as shown Bezels may include a key lock All bezels include two tabs on either side that you press in to release the bezel and its latches Refer to Figure 12 on page 13...

Страница 14: ...you replace or install FRUs you can inadvertently damage the sensitive electronic circuits in the equipment by simply touching them Electrostatic charge ESD that has accumulated on your body discharg...

Страница 15: ...hard disk drive supplied in special hot swappable hard drive carrier that fits in a disk slot Disk slots are accessible from the front of the server Refer to your product documentation to determine i...

Страница 16: ...tem wait at least 6 seconds before sliding the next disk drive assembly into position Identifying the faulted disk drive assembly Consult your product documentation on how to identify a faulted disk a...

Страница 17: ...ve assembly A B CL4881 3 Unpack the replacement disk drive assembly and save the packing material for returning the faulted disk drive assembly 4 Install the replacement disk drive assembly Figure 15...

Страница 18: ...rvice warranties Refer to your product documentation for information on which components are FRUs Should any non FRU component fail you must replace the entire server To replace the server perform the...

Страница 19: ...acement server Removing the bezel The front of the server may be covered by a bezel Bezels are application specific and may not appear as shown Bezels may include a key lock If the server has a bezel...

Страница 20: ...er Besch digung des Ger tes bitte das Geh use nicht ohne die Hilfe einer zweiten Person anheben und einbauen Il contenitore pesante e dev essere installato nel rack da due persone Per evitare danni pe...

Страница 21: ...t of the server 4 Being prepared to support the full weight of the server slowly pull the server forward and remove it from the cabinet Figure 20 on page 21 Figure 20 Releasing the inner rail locks an...

Страница 22: ...are installing the part 2 Unpack the part and place it on a static free surface 3 If the part is a replacement for a faulted part save the packing material to return the faulted part Attaching the inn...

Страница 23: ...ng the server until the studs fit securely into the small end of the rail notches An audible click indicates that the rail is secure Figure 22 Attaching an inner rail to the server CL4891 1 2 Attachin...

Страница 24: ...en Person anheben und einbauen Il contenitore pesante e dev essere installato nel rack da due persone Per evitare danni personali e o all apparecchiatura non tentare di sollevare ed installare in un r...

Страница 25: ...er rail without the server attached Figure 25 Inner rail over the first part of ball bearing retainer assembly CL5094 4 Once the inner rails are properly engaged with the ball bearing retainer assembl...

Страница 26: ...nstalling the bezel If a bezel covered the front of the server reinstall the bezel using the procedure that follows Refer to Figure 28 on page 27 while performing the procedure Procedure 1 Pushing on...

Страница 27: ...product Removing the slide rails from the cabinet If you ever need to remove the rails from the cabinet use the procedure that follows Procedure 1 On each rail remove the small stabilizer screw that...

Страница 28: ...b Slide the rail out of the channel and remove it from the cabinet Figure 30 Releasing the rail from the cabinet channels CL4856 Rear A B 28 EMC SVR I1U 1304 Server Installation and Maintenance Guide...

Страница 29: ...es of merchantability or fitness for a particular purpose Use copying and distribution of any EMC software described in this publication requires an applicable software license EMC EMC and the EMC log...

Отзывы: