2
2-14
EMC Disk-Array Processor Enclosure (DPE) Deskside Model FC4400/4500 Hardware Reference
Installing a Deskside DPE
When you connect multiple DAEs using the same Fibre Channel
arbitrated loop, retiming is required to maintain signal integrity. The
drive modules in each DAE must provide this timing, and each DAE
must be configured with at least two operational drive modules per
enclosure, one in an even numbered slot, and one in an odd numbered
slot (only one is required for the last DAE in the chain).
If you are installing a highly available deskside DPE, we
recommend that you plug the PDUs into separate ac source
circuits.
13. Plug the PDU ac input power cord(s) into the ac source
receptacle(s).
Do not power up a DPE without at least one LCC installed.
14. Set the power switch on each PDU to 1 (on).
Figure 2-12
Turning Power On
The Active light on each power supply, which is visible through
the drive fan pack, should be on. If it stays off, remove the drive
fan pack and ensure that the power switch on the power supply is
set to 1 (on) (see Chapter 3).
Power switch
Содержание FC4400
Страница 6: ...EMC Disk Array Processor Enclosure DPE Deskside Model FC4400 4500 Hardware Reference vi Contents ...
Страница 10: ...x EMC Disk Array Processor Enclosure DPE Deskside Model FC4400 4500 Hardware Reference Figures ...
Страница 12: ...xii EMC Disk Array Processor Enclosure DPE Deskside Model FC4400 4500 Hardware Reference Tables ...
Страница 16: ...xvi EMC Disk Array Processor Enclosure DPE Deskside Model FC4400 4500 Hardware Reference Preface ...
Страница 128: ...g 6 EMC Disk Array Processor Enclosure DPE Deskside Model FC4400 4500 Hardware Reference Glossary ...
Страница 134: ...EMC Disk Array Processor Enclosure DPE Deskside Model FC4400 4500 Hardware Reference i 6 Index ...