![EMC FC4400 Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/emc/fc4400/fc4400_hardware-reference-manual_2399719077.webp)
3
Replacing the SP Fan Pack
3-17
Servicing and Upgrading a Deskside DPE
Replacing the SP Fan Pack
CAUTION
!
Handle a fan pack gently and use an ESD wristband. Do not
remove a faulty fan pack until you have a replacement available.
You can remove the fan pack when the DPE is powered up. If the
pack is removed for more than two minutes, the SPs and disk
modules power down. The SPs and disk modules power up when
you reinstall the SP fan pack.
Removing the SP
Fan Pack
1. At the front of the deskside DPE, grasp the SP fan pack cover at
its sides and pull it from its ballstud mounts as shown below.
Figure 3-8
Removing the SP Fan Pack Cover
2. While pressing the latches of the fan pack inward, grasp the
handles and gently pull the fan pack out as shown.
Ballstud
SP fan pack cover