IEC62368 policy for Hatteland Technology products
IND100078-80
Authority
Description
Children
This equipment is not suitable for use in locations where children are likely to be present.
Ordinary person/
Sailor/End-User
Not allowed to open unit.
Not allowed to install the unit.
Not allowed to terminate/connect cables to the unit.
Instructed person
Allowed to open hatches/latches which does not require tools, such as Disktrays.
Allowed to open "battery-hatch" to change the battery even if tools are required.
Allowed to install the unit.
Allowed to terminate/connect cables to the unit indoors.
Skilled person
Allowed to open and disassemble the unit.
Allowed to install the unit.
Allowed to terminate/connect cables to the unit indoors and outdoors.
Allowed to terminate/connect earth/ground wire.
Note: Be aware that additional definition for “skilled person” may apply, country dependent.
Conditions
Description
AC power net Class
Class 1.
Pollution degree 2.
Over voltage category 2.
Transient requirement
External circuits are considered to be installed wholly within the same building structure.
Battery
Obligated to use battery specified for the product.
Altitude
Products are designed for a max operating altitude of 2000m.
Installation
Description
Mounting brackets
Only bracket defined/specified for the unit is allowed.
AC power cord
When installed it shall be possible to disconnect the unit from the AC power net
i.e. possible to reach AC connecter.
Transient requirement
External circuits are considered to be installed wholly within the same building structure.
Earthing
Obligated to use defined earthing material/method specified for the unit.
Minimum protective bonding conductor size of copper conductors:
Wire: Minimum 1,5mm
2
but Hatteland Technology recommends 2,5mm
2
(AWG12)
marked yellow/green.
Outdoor
Units with IP66/67-rated fronts can be used in outside environments, provided that the
console they are fitted in fulfil certain requirements.
- There must be a fully water/dustproof seal between the IP66 front and the console.
- Dust/water ingress protection of console. (Unit/product is rated for pollution degree 2).
- Humidity/condensation control in console.
- Thermal management in console (so units can operate within rated temperature range).
Units with IP20/IP22 shall not be used outdoor.
Outdoor Installation
Appropriate RCD with ground current rating of 20mA or less shall be used.
Содержание Hatteland Technology HTC03 AC Series
Страница 8: ...8 This page left intentionally blank...
Страница 9: ...9 General...
Страница 15: ...15 Installation...
Страница 33: ...33 This page left intentionally blank...
Страница 41: ...41 Specifications...
Страница 44: ...44 This page left intentionally blank...
Страница 45: ...45 Specifications Factory Options...
Страница 56: ...56 This page left intentionally blank...
Страница 57: ...57 Specifications Accessories...
Страница 60: ...60 IND100129 238 Specifications VSDDPVGA340 HT DPM2VGAF A1 DisplayPort to VGA adapter...
Страница 61: ...61 IND100129 255 Specifications RC3473 HT DPM2DVI DF A1 DisplayPort to DVI adapter...
Страница 63: ...63 Technical Drawings...
Страница 66: ...66 This page left intentionally blank...
Страница 67: ...67 Technical Drawings Accessories...
Страница 76: ...76 This page left intentionally blank...
Страница 77: ...77 Appendixes...
Страница 82: ...82 Appendix IND100077 227 BIOS Overview and functions BQ370 MH3 BIOS Step Ver 0 1...
Страница 110: ...110 BIOS Overview and functions Appendix IND100077 227 BQ370 MH3 BIOS BQ370 MH3 BIOS 29 5 Chipset...
Страница 148: ...148 Appendix IND100077 24 User Notes...
Страница 150: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...