Configuration
ELTROPLAN-REVCON
page 61
6
Configuration
The coding of the jumpers enables different driving possibilities and different
internal functions in accordance to specific error messages.
In the following different definitions are explained which result from the spe-
cific possibilities of coding!
a) „Autostart“
Autostart means that the device is starting with a delay-time of about 1 sec. af-
ter connecting mains voltage automatically ("automatically switch-on").
Coding via jumper, see figure 4.4.4.1:
J1 closed : Autostart
If the unit should not start automatically despite the phase failure control is dis-
abled, during the switch on process the terminals 7 and 8 have to be bridged till
4 s after switching on. To start the backfeeding afterwards a short impulse has
to be given on the RESET input.
b) „Switch on“ - „Switch off“
„Switch off“ means that the driving of the semiconductors and the power feed-
back will be interrupted. A braking operation of the frequency inverter with
power feedback is no longer possible.
„Switch-on“ is the activation of driving the semiconductors.
c) „Storage“
The unit is equipped with an error storage where special failures can be as-
signed to. Stored error messages have to be confirmed by RESET or interrup-
tion of mains supply. "Storage" always leads to a "switch-off" and to a collec-
tive-error-relay tripping.