_________________________________________________________________________________
_________________________________________________________________________________
TAU-72.IP/TAU-36.IP Universal Network Terminal 201
2.
Description of the messages transmitted TAU
Event
Importance Description
OID
Note
fxs72VbatAlarmTrap
MAJOR
The voltage Vbat =% 1 $ d in beyond the permissible limits (38-
72V)
1.3.6.1.4.1.35265.3.6.1
Option 1: voltage
fxs72VringAlarmTrap
MAJOR
The voltage Vring% 2 $ d =% 1 $ d beyond the permissible limits
(100-120V)
1.3.6.1.4.1.35265.3.6.2
Option 1: voltage
Option 2: the number of the
inductor (1 or 2)
fxs72TemperatureAlarmTrap
MAJOR
The temperature sensor% 2 $ d =% 1 $ d greater than the
maximum value (90°C)
1.3.6.1.4.1.35265.3.6.3
Option 1: The temperature
Option 2: The number of the
temperature sensor (1-4)
fxs72FanAlarmTrap
MAJOR
Fan% 1 $ d is on, but does not rotate
1.3.6.1.4.1.35265.3.6.4
Option 1: The number of fan
fxs72SSwAlarmTrap
MAJOR
No registration on the MGC / SSW
1.3.6.1.4.1.35265.3.6.5
It is used for software version
- Megaco
fxs72PortAlarmTrap
MINOR
Port% 1 $ d is locked
1.3.6.1.4.1.35265.3.6.6
Option 1: The port number
fxs72VbatOkTrap
CLEAR
The voltage Vbat OK
1.3.6.1.4.1.35265.3.7.1
fxs72VringOkTrap
CLEAR
The voltage Vring% 2 $ d OK
1.3.6.1.4.1.35265.3.7.2
Option 2: the number of the
inductor (1 or 2)
fxs72TemperatureOkTrap
CLEAR
The temperature sensor% 2 $ d OK
1.3.6.1.4.1.35265.3.7.3
Option 2: The number of the
temperature sensor (1-4)
fxs72FanOkTrap
CLEAR
Fan% 1 $ d is operating normally
1.3.6.1.4.1.35265.3.7.4
Option 1: The number of fan
fxs72SSwOkTrap
CLEAR
There is a registration MGC/SSW
1.3.6.1.4.1.35265.3.7.5
It is used for software version
- Megaco
fxs72PortOkTrap
CLEAR
Port% 1 $ per unlocked
1.3.6.1.4.1.35265.3.7.6
Option 1: The port number
fxs72VmodeSwitchTrap
INFO
Diet changed -% 1 $ a in
1.3.6.1.4.1.35265.3.7.10
Option 1: the new regime:
1 - 60 V
2 – 48 V
fxs72FansSwitchTrap
INFO
Fan status changed
1.3.6.1.4.1.35265.3.7.11
Option 1:
0 - included
1 - included
fxs72updateFwFail
MINOR
Error while updating software
1.3.6.1.4.1.35265.3.6.20
Option 1: The type of error
fxs72updateFwOk
INFO
Updated Software
1.3.6.1.4.1.35265.3.7.20
fxs72BpuAlarmTrap
CRITICAL
No communication with the BPU
1.3.6.1.4.1.35265.3.6.12
fxs72BpuOkTrap
CLEAR
Contact Bending restored
1.3.6.1.4.1.35265.3.7.12