_________________________________________________________________________________
_________________________________________________________________________________
TAU-72.IP/TAU-36.IP Universal Network Terminal 113
blocked when the phone is offhook. This blocking will be performed after the 'busy' tone is played to the
subscriber's phone for two minutes. Upon the expiry of two-minute interval, a loud triple-tone will be played to
the subscriber's phone notifying them that the phone is offhook.
To save the changes you must click
'Save'
button.
When you click on ‘Hide blocking info’ button information on blocking will be removed.
When you click ‘Hide all’ button are removed the results of tests of all types.
Port test
'Run test'
button, located against each port, allow s to test the subscriber line associated with
this port. When the button is pressed, the test will be executed (it may take up to one minute.) To
see the results when the test finishes, hover the mouse cursor over the
'result'
link located against
the respective port, or open the test results window by clicking the link:
Description of '
Port test results
' informational window:
—
Common result
—test result status.
—
Foreign DC voltage В (RING), V—foreign voltage in В wire (RING), V.
—
Foreign DC voltage A (TIP), V—foreign voltage in A wire (TIP), V.
—
Line supply voltage, V
—line power supply voltage, V.
—
Ringing voltage, V
—call voltage, V.
—
Resist A (TIP)–B (RING), kOm—resistance between А (TIP) and В (RING) wires, kΩ.
—
Resist A (TIP)-GND, kOm
—resistance between
А (TIP)
wire and ground
GND
, kΩ.
—
Resist B (RING)-GND, kOm
—resistance between
B (RING)
wire and ground
GND
, kΩ.
—
Capacity A (TIP)–B (RING), mkF—capacity between А (TIP) and В (RING) wires, µF.
—
Capacity A (TIP)-GND, mkF
—capacity between
А (TIP)
wire and ground
GND
, µF.
—
Capacity B (RING)-GND, mkF
—capacity between
B (RING)
wire and ground
GND
, µF.
Do not launch the test for multiple ports simultaneously. Port test cannot be interrupted!
Test results description:
–
OK
—line test has been completed successfully.
–
TEST FAILURE
—invalid operand values were calculated during measurement. For example, division by