13
The energy meter has two slots for extension modules, slot 1 and slot 2 (Fig. E).
In addition, the meter
can be equipped with an integrated radio.
Fig. E
Slots
1 Slot
1
2 Slot
2
3 Fixing
clip
NOTE
Inserting a module into slot 2 immediately disables the internal radio function!
The meter recognizes automatically which module is inserted. This is shown in the
display loop 3 based on a module code. See also point 6.2.1.
NOTE
If other external devices are connected to the meter, these must be of the safety
extra-low voltage (SELV) type and comply with EN 60950-1.
3.6.1 Communication modules
The meter supports three communication channels over the same or different interfaces. If the meter
has an integrated radio, it is possible to use the two slots for modules. The protocol is different for
each of the two modules and is preset ex works, but can be programmed to customer-specific
requirements using the IZAR@SET software. The content of the radio protocol is the same as the
content from slot 2. Each module has its own primary address. Both modules have one secondary
address, which is set to the serial number ex works. The meter is equipped with automatic baud rate
detection.
M-Bus module
The M-Bus communication module is a serial interface for communication with external devices (M-
Bus repeater), e.g. IZAR CENTER. It is possible to connect more meters to one M-Bus master.