3.5.1 Battery
A 3.6 V DC lithium battery is fitted in the standard version. The battery is not to be charged or short-
circuited. Ambient temperatures below 40 °C extend the life of the battery.
DANGER
There is a risk of explosion if the battery is replaced with the wrong type of
battery.
3.5.2 Overview of the measuring rates
The following table shows the lifetime of the batteries depending on the standard measuring rates.
Customer versions can differ from the standard measuring rates in the measuring rate and battery
lifetime.
1
: for “moderate” ambient temperature. Temperature above 35°C reduces the lifetime.
The temperature at storage of the meter in a warehouse shall be less than 35°C.
The calculation of flow and volume is will be done every 2 seconds
After that the display is updated every 2 seconds.
To save energy the meter tries to do all its operations like metering, calculation and updating the
display at the same time.
Battery
lifetime
1
[Years]
Radio sending
interval
Measuring rate
(independent of radio)
A-Cell
1
Measuring rate
without radio/without modules
10,5
without
radio
Volume
Temperature
1s
16s
868MHz
10
180s
434MHz
10
180s
Quick Mode
6,5
180s
Volume
Temperature
1s
4s
7
without
radio
D-Cell
Measuring rate
without radio
16
-
Volume
Temperature
1s
4s
868MHz
16
12s
434MHz
16
12s
Mains unit
Measuring rate
without radio
unlimited
12s
Volume
Temperature
8Hz
2s
868MHz
unlimited
12s
434MHz
unlimited
12s