Gold Twitter Installation Guide
MAN-G-TWI (Ver. 2.000)
|Feedback Connector FDB|
www.elmomc.com
48
Table of Contents
Pin
FDB
Signal
Function
11
PortA_ENC_INDEX-
Port A - index complement
12
PortB_EN/A Port B – index
RESOL
Vref
13
HA
Hall sensor A input
14
PortC_ENCO_A-
Port C- channel A complement output
15
HB
Hall sensor B input
16
PortC
Port C- channel A output
17
HC
Hall sensor C input
18
PortC_ENCO_B-
Port C - channel B complement output
19
+5VE
E5 V supply @ Limit 250 mA
20
PortC
Port C - channel B output
21
COMRET
Common return
22
PortC_ENCO_INDEX-
Port C - index complement output
23
COMRET
Common return
24
PortC_ENC
Port C - index output
Table 8: Connector FDB – Feedback
For short distances between the drive and control, 0.5 to 1.0 m wires can be used and shielding
is not required.
For longer distances than 1.0 m and/or high EMI environment, shielded and
twisted wires should be used. Drain wires should be connected to Elmo COMRET.