Gold Twitter Installation Guide
MAN-G-TWI (Ver. 2.000)
|Control Supply Input Voltage (VL)|
www.elmomc.com
13
Table of Contents
4.5.
Control Supply Input Voltage (VL)
The Control Supply input voltage (VL) must be either SELV or PELV rated.
Feature
Unit
Details
Standard CAN
Input range for G-TWIXXX/YYYSZ
(Blank)
V
12V – 40V
Input range for G-TWIXXX/YYYSZ
S
or
H
V
11V – 95V
Power consumption
(including 5 V/200 mA for encoder)
W
<2.5W
ETHERCAT
Input range for G-TWIXXX/YYYEZ
(Blank)
V
14V – 40V
Input range for G-TWIXXX/YYYEZ
S
or
H
V
11V – 95V
Power consumption
(including 5 V/200 mA for encoder)
W
<4W
4.6.
Product Features
Main Feature
Details
Presence / No.
STO
5V Logic Level, Opto isolated from the Control
section
√
Digital Input
Option
5V Logic Level (Internally connected to
COMRET)
6
Digital Output
Option
5V logic (Internally connected to COMRET)
2
3.3V logic (Internally connected to COMRET)
2
Analog Input
Differential ±10V
1
Single Ended
1
Feedback
Standard Port A, B, & C
√
Communication
Option
USB (only for EtherCAT version)
√
EtherCAT
or
√
CAN
√
RS232 TTL level
√
Standard RS232
√
Содержание 1/100
Страница 78: ...Gold Twitter Installation Guide MAN G TWI Ver 2 000 Heat Dissipation www elmomc com 78 Table of Contents ...
Страница 79: ...Gold Twitter Installation Guide MAN G TWI Ver 2 000 Heat Dissipation www elmomc com 79 Table of Contents ...
Страница 88: ... Accessories Heat Sink Dimensions www elmomc com 88 Table of Contents ...