This power supply unit meets the essential requirements of the following EU Directives: 

 

 

Functional standard: 

EN54-4:1997 +A1 +A2 

Environmental Class II 

Certification Body: 

Underwriters Laboratory 

Declaration of Performance 

DOP2014/04 

DOP2014/05 

 

 

This product falls within the scope of EU Directives 2002/96/EC Waste Electrical and Electronic Equipment 

(WEEE) and 2006/66/EC (Battery). At the end of life, the product must be separated from the domestic 

waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all national 

and local regulations. 

Before disposal of the product, any batteries must be removed, and disposed separately via an appropriate 

approved battery disposal route in accordance with all national and local regulations. Package used batteries 

safely for onward transport to your supplier, collection point or disposal facility. 

 

Caution: Risk of fire or explosion 

if bare battery wires are allowed to touch. 

 

See Specification for battery type information. The battery is marked with the crossed out wheelie bin 

symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). 

 

 

 

The packaging supplied with this product may be recycled. 

Please dispose of packaging accordingly. 

C

OMPLIANCE

 

CPR: 

305/2011 EU 

EMC: 

2004/108/EC 

Low Voltage: 

2006/95/EC 

WEEE: 

2002/96/EC 

RoHS: 

2011/65/EU 

 

D

ISPOSAL OF 

P

RODUCT AT 

E

ND OF 

L

IFE

 

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание STX2402 Series

Страница 1: ...relay fault output signal i loss of mains and ii battery fault charger fault and loss of output In addition there is an optional plug in serial interface that can provide diagnostic and fault reportin...

Страница 2: ...I 2 x 17 Ah 12 V PS12170 NP17 12I Battery Charging Constant current bulk charging to 80 capacity within 24 hours Float charging to 100 within 48 hours Eco charging and check every 24 hours for up to 8...

Страница 3: ...tion Mains present Battery healthy None OPEN CLOSED Standby Mode Mains lost Battery driving load Investigate loss of mains CLOSED OPEN Fault Present Blown fuses Battery fault Internal fault Investigat...

Страница 4: ...lled no further than 10cm from the CIE and close coupled byconduit This unit must be fed from a mains power source having a separate approved disconnect device and fitted with a fuse or other over cur...

Страница 5: ...eing used to power the CIEdirectly 8 Fix to wall or other structure in correct orientation i e with hinge on left hand side using screws of sufficient size and length through the mounting holes 9 Prot...

Страница 6: ...hole Figure 3 Connections Battery Select Mains ON Diagnostic LED Fault LED L E N Mains Temperature Sensor connect To Load 6 Re apply mains Verify that the green Mains LED illuminates and the yellow Fa...

Страница 7: ...t the green Mains LED illuminates and the yellow Fault LED extinguishes 18 If connected verify that the EPS Fault monitor shows a closed contact and the GEN PSU Fault monitor shows a closed contact 19...

Страница 8: ...batteries must be removed and disposed separately via an appropriate approved battery disposal route in accordance with all national and local regulations Package used batteries safely for onward tra...