How to replace the ultrasonic generator
68
SM/Transsonic_LC/1104/D
© Elma GmbH & Co KG
Electric connections
and fixation of
transistors
Illustration 14.2.1. Generator print T460 – T470H; LC60H
Supply cables timer >> generator print.
Polarization irrelevant.
Plug contact 4.8 mm: HF output (+) to transducer system.
Plug contact 6.3 mm: HF output (-) to transducer system.
Earthing connection generator print >> earthing point bottom
plate (units made since 2000).
Holding clamps for transistors.
Insulating sleeves for transistors.
A
B
C
D
E
F
A
B
C
D
E
F
Содержание LC130H