How to replace the ball valve
58
SM/Transsonic_LC/1104/D
© Elma GmbH & Co KG
Mounting of the 1/2“
drain duct
Illustration 12.1.4. Loosen the lock nut with a 32 mm fork wrench anti-
clockwise
Illustration 12.1.5. Heat the Loctite thread sealing with a hot air fan
Illustration 12.1.6. Secure the duct nipple (A) with a pipe wrench to
avoid an opening of the sealing in the duct angle (B).
A
B