How to replace the interference filter
60
SM/Transsonic_LC/1104/D
© Elma GmbH & Co KG
Earthing contacts.
Mains supply zero (blue).
Interference filter coil.
F
G
H
13.2
Interference filter on T460 – T700H
The interference filter is arranged on a separate printed board.
On units made since 1992, there are fuses integrated on the
interference filter. If the fuses are blown there is usually a short
circuit in the heating element.
In order to find the cause we recommend to interrupt the cables
of the heating and to test the unit again with new fuses.
Illustration 13.3.1. Mounted and connected interference filter
Supply cables interference filter >> timer input.
Polarization irrelevant. On units with heating the cable for the
heating is connected to the twin contacts.
Supply cables timer output >> generator.
Polarization irrelevant.
Mains supply phase (brown).
Earthing contacts.
Mains supply zero (blue).
Mains supply heating.
Interference filter coil.
B
F
D
E
C
G
F
A
A
B
C
D
E
F
G