Barrier maintenance
WARNING!
Rotating and/or linear movable components can cause
serious injuries.
Do not reach into moving parts or handle any moving
components during operation.
Turn the appliance off before any maintenance work,
repair work or other work and secure it against
unintentional restarting.
Maintenance P 2500-5000
The maintenance intervals must be decided individually as they are dependent
on the application and the frequency of use. We recommend maintenance at
least once every six months.
1. Check the balancing springs. In case of a faulty spring, all springs must be
replaced simultaneously.
2. Check that the boom is perfectly balanced by the springs (see page 28).
3. Check barrier housing and boom for accidents and damage and replace
where necessary.
4. Ensure that the potential earthing cable is still connected to the housing
and to the door.
5. Check that the operating instructions are complete.
6. Check that all safety equipment works properly (induction loops,
photoelectric barriers, power reversal,...).
7. Check that the barrier is still secure on the foundation.
8. Check the plastic screws (M8x45) or steel screws (M8x70) at the boom
connector.
9. Check the emergency release for correct functioning (by activation).
10. Perform a visual inspection and tighten screws where necessary.
11. Grease the guide bars using multi-purpose grease (temperature range -
30°C to +70°C / -22°F to +158°F). Remove excess grease.
Содержание P 2500
Страница 14: ...P 2500 P 5000 13 4 Declaration of incorporation Drawing 2 ...
Страница 20: ...P 2500 P 5000 19 7 2 Mounting dimensions Drawing 3 ...
Страница 47: ...P 2500 P 5000 46 8 4 Circuit diagram Drawing 34 ...
Страница 48: ...P 2500 P 5000 47 Drawing 35 ...
Страница 49: ...P 2500 P 5000 48 Drawing 36 ...
Страница 50: ...P 2500 P 5000 49 Drawing 37 ...
Страница 51: ...P 2500 P 5000 50 Drawing 38 ...
Страница 52: ...P 2500 P 5000 51 Drawing 39 ...
Страница 55: ...P 2500 P 5000 54 10 Layout exploded drawing Drawing 41 ...